138090_Rev_F 7.29.10
Jøtul GF 600 DV II Firelight

Specifications

Input Rates
Natural Gas
40,000 BTU/hr. maximum input
23,900 BTU/hr. minimum input
Propane
40,000 BTU/hr. maximum input
20,300 BTU/hr. minimum input
Inlet Pressure:
Natural Gas:
5.0 WC (1.24 kPa)
Propane:
12.0 WC (2.99 kPa)
Manifold Pressure:
Natural Gas:
1.2 WC (0.30 kPa)
Propane:
2.9 WC (0.72 kPa)
Piezo Ignitor / Standing Pilot
Weight: 260 lbs.
THIS FIREPLACE IS SHIPPED FROM THE FACTORY
FOR USE WITH NATURAL GAS ONLY. IF USE WITH
PROPANE IS DESIRED, THE APPLIANCE MUST
FIRST BE CONVERTED USING THE FUEL CONVER-
SION KIT PROVIDED, #155893. CONVERSION
SHOULD BE MADE BEFORE THE APPLIANCE IS
INSTALLED.

General Information

THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A
QUALIFIED SERVICE AGENCY.
The installation and repair of this appliance must be
done by a qualified service person. Failure to properly in-
stall and maintain this heater could result in an unsafe or
hazardous installation, which may result in a fire, explo-
sion, property damage, personal injury or loss of life.
This appliance should be inspected before use and at
least annually. More frequent cleaning may be required
due to excessive lint from carpeting, bedding material,
etc. It is imperative that control compartments, burners,
and circulating air passageways of the appliance be kept
clean.
THIS APPLIANCE MUST NOT BE CONNECTED TO A CHIM-
NEY OR FLUE SERVING ANY OTHER APPLIANCE.
The installation must conform to local codes. Your local
Jøtul dealer can assist you in determining what is re-
quired in your area for a safe and legal installation. Some
areas require a permit to install a gas burning appliance.
Always consult your local building inspector, or authority
having jurisdiction, to determine what regulations apply
in your area.
4
MIN
MAX
7.0 WC (1.74 kPa)
14.0 WC (3.23 kPa)
MIN
MAX
3.5 WC (0.95 kPa)
11.0 WC (2.74 kPa)
28 1/2"
(72.5 cm)
Leg Width
16"
(41 cm)
24"
(61 cm)
Rear Exit Flue Collar Height and Centerline
31"
(79 cm)
Top Exit
Flue
31 1/8"
(79 cm)
Collar
Height
31 3/4"
(80.5 cm)
Co-Linear
Transition
27 3/4"
Adaptor
(70.5 cm)
Height
Exhaust Out-
let Centerline