Co-linear Hearthmount Installation
The GF 600 DV II Firelight can be installed using
a Hearthmount Co-linear Flexible Vent System,
designed for installation into a solid fuel-burning
masonry fireplace. See Figures 6 and 6a.
Refer to the vent manufacturer's instructions for
venting components and installation details.
Installation of approved Co-linear Adapter directly
off the rear of the stove. (No length of pipe prior to
the adaptor).
Only 3" listed flexible gas vent liners may be used
in this installation.
Installation of a Chimney Top Kit will provide
a seal at the top of the chimney. The fireplace
damper may be removed and no further block-off
is required. See fig. 6.
WARNING: FAILURE TO POSITION THE PARTS AND STOVE IN
ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE
ONLY PARTS SPECIFICALLY APPROVED FOR USE WITH THIS
APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PER-
SONAL INJURY. BE SURE TO MAINTAIN THE PROPER CLEAR-
ANCES TO COMBUSTIBLES AS DEFINED IN THIS MANUAL
AND IN THE INSTRUCTIONS PROVIDED WITH EACH VENT
COMPONENT.
IMPORTANT NOTICE:
THE USE OF AN EXISTING CHIMNEY AS
AN AIR INTAKE IS NOT COVERED UNDER
THE ANSI Z21.88-1999-CSA 2.33-M99 TEST
METHODS AND RESULTING ITS/WHI PRODUCT
CERTIFICATION. THE CODE AUTHORITY HAVING
JURISDICTION MUST BE CONSULTED PRIOR
TO PROCEEDING WITH THIS INSTALLATION
METHOD.
DO NOT FULLY CLOSE
EXHAUST RESTRICTION ON
CO-LINEAR VENT SYSTEMS.
High Wind Cap
Top Kit
Chimney Sealed
at Top
Co-linear
Exhaust Height:
Maximum - 40 ft.
(10.5 m)
Minimum - 7 ft.
(3 m)
3" Flex
Exhaust
Liner
3" Flex
Air Intake
Figure 6. Co-linear Hearthmount Vent System
138090_Rev_F
7.29.10
Exhaust
Intake
Co-linear
Appliance
Adaptor