Horizontal Termination

Exhaust Restriction: Under normal circumstances, no
exhaust restriction is recommended. Set the restriction
shutter to Position A - fully open, fig. 8, pg. 9.
Any horizontal termination must fall within the shaded
portion of the vent window matrix shown in fig. 9.
Use of 4" x 6 5/8" vent horizontally terminated,
requires that the Secondary Exhaust Baffle be
removed. See figs. 21 - 22.
Horizontal termination requirements:
1) If no vertical run, the minimum horizontal run is 6 in.
2) If no vertical run, the maximum horizontal run is 48 in.
3) Maximum vertical run is 20 ft.
4) With any vertical run, the maximum horizontal run is 15 ft.
Up to four 45° or two 90° elbows may be used in
addition to the starter elbow. The horizontal run
must be reduced by 5 feet for each additional elbow,
whether 45° or 90°.
The horizontal termination cap must maintain a 3"
clearance to any overhead combustible projections
2 1/2" or less. It must also maintain 12" clearance from
projections exceeding 2 1/2". See fig. 24.
Wall Cut-out Opening: A minimum 10" X 10" (250 mm
x 250 mm) square hole is required for proper pipe
clearances through a combustible wall.
DO NOT FILL AIR SPACE WITH ANY TYPE OF INSULATION.
Any horizontal run of vent must be level or have a
1/4 in. rise for every foot of run toward the termination
cap. NEVER ALLOW THE VENTING TO RUN DOWNWARD
FROM STOVE TO TERMINATION; DOWNWARD VENT
RUNS TRAP HEAT AND CAUSE HIGH TEMPERATURES TO
DEVELOP WITHIN THE VENT THAT COULD START A FIRE.
Install a Vinyl Siding Standoff (Simpson Dura-Vent
#950) between the vent termination and an exterior
wall covered by vinyl siding material to prevent
potential heat damage to the siding.
Direct vent terminals may not be recessed into a wall
or siding.
14
Figure 19.
4/6 Vent -
Mininimum / Maximum
run for horizontal
termination.
Min: 6" / (152 mm)
Max: 48" (122 mm)
Figure 20.
5/8 Vent - Minimum / Maximum horizontal vent -
no vertical run. 1/4 inch (6mm) rise per foot is required.
Figure 21.
Use 1/2" (10 mm) socket to remove nut from Primary Baffle
stud.
Primary Baffle
Figure 22.
Use 1/4" (6 mm) socket driver to remove Primary Baffle
from Secondary Baffle.
6”
152 mm
48”
122 cm
Primary Baffle