CAUTION: THESE INSTRUCTIONS MUST
REMAIN WITH THE HOMEOWNER.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury or loss of life.
– Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call you gas supplier from a
neighbor's phone. Follow the gas
supplier's instruction.
• If you cannot reach your gas supplier,
call the fire department.
– Installation and service must be
performed by a qualfied installer, service
agency or the gas supplier.
– In the Commonwealth of Massachusetts, a
carbon monoxide (CO) detector shall be
installed in the same room as the
appliance.
Installation and

Operation Instructions

ATTENTION : CES INSTRUCTIONS DOIVENT
DEMUERER AVEC LE PROPRIÉTERE D'UNE
MAISON.
AVERTISSEMENT: Assurez-vous de bien
suivreles instructions données dans cette
notice pour réduire auninimum le risque
d'incendie ou d'explosion ou pour éviter tout
dommage matériel, toute blessure ou la mort.
– Ne pas entreposer ni utiliser d'essence ni
d'autres vapeurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout
autre appareil.
– QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE
GAZ:
• Ne pas tenter d'allumer l'appareil.
• Ne touchez à aucum interrupteur. Ne pas
vous servir des téléphones se trouvant
dans le bâtiment où vous trouvez.
• Appelez immédiatement votre
fournisseur de gaz depuis un voisin. Suivez
les instructions du fournisseur.
• Si vou ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incendies.
– L'installatione l'entretien doivent être
assurés par un installateur ou un service
d'entretien qualifié ou par le fournisseur
de gaz.
1

Advertisement

Table of Contents
loading

Summary of Contents for Jøtul GF 300 DV

  • Page 1: Operation Instructions

    Installation and Operation Instructions ATTENTION : CES INSTRUCTIONS DOIVENT CAUTION: THESE INSTRUCTIONS MUST DEMUERER AVEC LE PROPRIÉTERE D’UNE REMAIN WITH THE HOMEOWNER. MAISON. AVERTISSEMENT: Assurez-vous de bien WARNING: If the information in these suivreles instructions données dans cette instructions is not followed exactly, a fire notice pour réduire auninimum le risque or explosion may result causing property d’incendie ou d’explosion ou pour éviter tout...
  • Page 3: Table Of Contents

    Table of Contents Service Tools ..........4 Specifications ........... 4 Jøtul GF 300 DV Allagash General Information ....... 5 Safety Information ........6 Direct Vent Gas Heater Installation Requirements Location ..........6 Manufactured and Distributed by: Jøtul AS Hearth Protection ......6 Fredrikstad, Norway Clearances ..........
  • Page 4: Service Tools

    GF 300 DV Specifications Specifications 27 1/2” 698 mm Input Rates Natural Gas 26,000 BTU/hr. maximum input 14,000 BTU/hr. minimum input Propane 22 1/4” 26,000 BTU/hr. maximum input 565 mm 14,000 BTU/hr. minimum input Inlet Pressure: Natural Gas: 5.0 WC (1.24 kPa) 7.0 WC (1.74 kPa)
  • Page 5: General Information

    General Information THIS HEATER MUST BE INSTALLED AND MAINTAINED Glass Panel BY A QUALIFIED SERVICE AGENCY. Do not operate this appliance with the glass The installation and repair of this appliance must be front removed, cracked, or broken. Replacement done by a qualified service person. Failure to prop- of the glass should be done by a licensed or erly install and maintain this heater could result in qualified service person.
  • Page 6: Safety Information

    Also, “fire-rated” sheet NEVER store or use gasoline or any other flammable rock is considered combustible. vapors or liquids in the vicinity of the GF 300 DV gas stove. Hearth Requirements Never burn any other materials in your GF 300 DV...
  • Page 7: Clearances

    Stove and Vent Clearance Requirements Minimum Clearances from the Stove 2” to Combustibles: See figs. 2-4. (51 mm) Rear: 2” (51 mm) To Rear Wall Ceiling: 35 1/4” (870 mm) Corner: 2” (51 mm) 3” 3” Sides: 3” (76 mm) Mfg.Serial No.
  • Page 8: Vent Requirements

    Vent Restriction The GF 300 DV is equipped with an Exhaust Restrictor The Jøtul GF 300 DV gas stove may be installed with a Plate which enables you to regulate the flow of exhaust vertical or horizontal termination and must conform to gas.
  • Page 9: Vertical Termination

    See Fig. 6 with top plate removed. Detail Vertical Vent Termination The Jøtul GF 300 DV can be vertically vented through a ceiling or to a roof termination with the following guidelines: The termination should fall within the shaded areas of the grids depicted in the Vent Window diagrams on pages 10 - 11.
  • Page 10 Vent Windows for Natural Gas 35 Ft. COLINEAR VENT (10.67 m) 35 Ft. 35 Ft. (10.67 m) (10.67 m) COAXIAL VENT 30 Ft. (9.14 m) Up to four 45° or two 90° elbows 25 Ft. permitted in (7.62 m) addition to the 25 Ft.
  • Page 11 Vent Windows for Propane COLINEAR VENT 35 Ft. (10.67 m) 35 Ft. (10.67 m) COAXIAL VENT 30 Ft. (9.14 m) Up to four 45° or two 90° elbows permitted in 25 Ft. (7.62 m) addition to the 25 Ft. starter elbow. (7.62 m) 20 Ft.
  • Page 12: Co-Linear Termination

    Intake Air Co-linear Vent Installation Max. Co-linear Height - 35 ft. The GF 300 DV may be vented through a masonry or (10.66 m) Class A prefabricated chimney using a Co-linear Flexible Min. Co-linear Vent system approved for use with a solid-fuel burning Height - 8 ft.
  • Page 13: Coaxial Chimney Conversion

    Exhaust Termination Cap Conversion Cap Adaptor- included in The GF 300 DV is approved for use with Simpson Dura- Intake Air #934 Kit vent Chimney Kit #934 in a masonry chimney or a prefabricated solid fuel listed chimney. These installation requirements must be followed: 4”...
  • Page 14: Horizontal Termination

    12” Horizontal Termination Any horizontal termination must fall within the shaded portion of the vent window graph illustrated in figs. 9 or 11. For Snorkel Terminations, see below. Any horizontal termination except a snorkel termination, 24” must include: 14” 610 mm 335 mm 56 1/2”...
  • Page 15: Vent Terminal Clearances

    Horizontal Termination Clearance Figure 20. Vent Terminal Clearances - ANSI Z21.88-2002, CSA 2.33-2002, and National Fuel Gas Code. A A A A A = Clearance above grade, veranda, porch , deck, or 1 1 1 1 1 Clearance above paved sidewalk or a paved driveway balcony : 12 inches (30 cm) minimum.
  • Page 16: Mobile Home Installation

    Mobile Home Installation WARNING: The GF 300 DV can be installed for use in a mobile home THE CONVERSION KIT IS TO BE INSTALLED BY AN AUTHORIZED JØTUL SERVICE TECHNICIAN IN in the U.S. and Canada provided: ACCORDANCE WITH THE MANUFACTURER’S 1.
  • Page 17 Fuel Conversion Procedure Air Shutter 1. Turn off gas supply to stove. 2. Remove the stove Top Plate. 3. Disengage the two Glass Frame Latches at the top of the firebox. See illustration on page 5. Carefully lift the glass panel up and out of the stove. Burner Pla Burner Pla Burner Pla...
  • Page 18: Gas Supply Connection

    Main Gas Valve 15. Install the new regulator: Be sure the new gasket is Apply small label. properly positioned and tighten screws securely. 16. Install the identification labels to the stove so that they can be seen by any person who may be servicing the stove.
  • Page 19: Gas Pressure

    11.0 Gas Pressure Correct gas pressure is essential for efficient and safe operation of the GF 300 DV gas stove. It is important that the correct pressure is established at the time of the installation. Proper gas pressure provides a...
  • Page 20: Air Shutter Adjustment

    Adjustment Use only a 750 millivolt DC two-wire circuit thermostat The GF 300 DV gas stove is shipped from the factory with this appliance. The thermostat should be placed in equipped to burn Natural gas. If the stove has been...
  • Page 21: Log Set Installation

    155370 before installing the logset..See page 27 and the instructions provided with that kit. The GF 300 DV logset must be installed before operating the burner. The logset includes four log pieces, packaged inside the firebox, and a quantity of ember stones packaged in the Miscellaneous Parts bag.
  • Page 22: System Check

    1” System Check (25mm) 3/8” 1/8” (8mm) (3mm) 1. PURGING THE GAS LINE: When lighting the appli- Min. Min. ance for the first time, it will take a few moments to clear the gas line of air. Once this purge is complete, the appliance will operate as described in the lighting instructions.
  • Page 23: Operation

    Operation Familiarize yourself with the controls of the GF 300 DV. Make sure that anyone else using the appliance is also familiar with the controls and operation procedures. Always follow the Lighting Instructions on the inside back cover of this manual and also located on the Rating Plate attached to the rear shroud.
  • Page 24: Maintenance

    FOR REPLACEMENT, USE ONLY JØTUL CERAMIC GLASS PANEL 220576. DO NOT USE ANY OTHER TYPE OF GLASS WITH THIS APPLIANCE. Your Jøtul GF 300 DV Allagash and its venting system should be inspected before use and at least annually by a qualified service technician.
  • Page 25: Optional Blower Installation

    1. Unpack and check the contents of the blower kit. The kit includes two Air Deflectors and two #7 x 1/2” screws that will not be used with the GF 300 DV Allagash stove. Contact your dealer if any damage is evident or parts are missing.
  • Page 26: Blower Operation

    Figure 44. Attach Blower to the Mounting Bracket with the wingscrew and connect wires to Snapstat and female control quick connect. Male Quickconnector Snapstat Connectors Female Quickconnector Wingscrew Blower Operation The optional variable-speed blower will enhance heat circulation around the firebox and out into the room. The blower is controlled by a heat activated switch (snapstat) that will ONLY function when the control switch is in AUTO setting.
  • Page 27: Optional Brick Kit Installation

    Optional Antique Brick Kit # 155648 CAUTION! THE BRICK PANELS AND LOG PARTS ARE EXTREMELY FRAG- ILE. HANDLE WITH CARE. Figure 48. Disengage the compression latches R R R R R ead ead these instruc these instruc these instruc these instruc these instructions bef tions bef tions bef...
  • Page 28: Illustrated Parts Breakdown

    NOT T T T T E: E: E: E: E: THE GAS CONTROL VALVE ASSEMBLY Parts Breakdown IS MOUNTED AT THE CENTER FRONT OF ALL STOVES BEGINNING WITH SERIAL NO. 30000. Figure 52. Illustrated Parts Breakdown - GF 300 DV Allagash...
  • Page 29: Replacement Parts List

    GF 300 DV Allagash Parts List Blue Black Blue Black Blue Black Blue Black Blue Black Iv Iv Iv Iv Ivor or or or oryu F F F F F Jøtul Ir Jøtul Ir Jøtul Ir Jøtul Ir Jøtul Iron...
  • Page 30 Record the following information to help your dealer determine what you will need for parts and service. GF 300 DV M M M M M ODEL NA ODEL NA ODEL NA ODEL NA ODEL NAME: ME: _________________________ SERIAL NUMBER: ________________________...
  • Page 31: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. A. A. A. A. A. This appliance has a pilot which must be lit •...
  • Page 32 This appliance must be installed in conformance with local and national building regulations. Before beginning the installation, it is important that the these instructions be carefully read and understood. Jøtul maintains a policy of continual product development. Consequently, products may differ in specification, color or type of accessories from those illustrated or described in various publications.

Table of Contents