138090_Rev_F 7.29.10
MAIN GAS
VALVE
REMOVE THE BLACK
RUBBER GASKET FROM
THE VALVE!
Figure 19. Regulator parts.
17. Install the identification labels to the stove so
that they can be seen by any person that may be
servicing the stove.
• Label A: Apply to back of stove.
• Label B: Apply to the Rating Plate.
• Small valve sticker: Apply to valve.
18. Install the Brick Panels, Log Set and Embers as
appropriate. See pages 18-19.
19. Adjust the primary Air Shutter and flame appear-
ance following instructions on page 20.
20. Reassemble the stove, apply gas to the system
and check for leaks using a soapy water solution
or gas sensor..

High Altitude Adjustment

The decreased atmospheric pressure of higher alti-
tudes affects heat value of gaseous fuels. Most gas
suppliers derate the gas intended for use at eleva-
tions above 2000 feet. Check with your gas supplier
before performing derate adjustment to the burner.
The Jøtul GF 600 DV II may be adjusted for altitude
over 2000 ft. (610 - 1371 m) for natural gas.
Check with your gas supplier and, if necessary, install
High Altitude Adjustment Kit 155808.
DO NOT DERATE FOR PROPANE.
For the U.S:
THE DERATING KIT MUST BE INSTALLED BY AN AU-
THORIZED SERVICE TECHNICIAN IN ACCORDANCE
WITH THE MANUFACTURER'S INSTRUCTIONS AND
ALL CODES AND REQUIREMENTS OF THE AUTHOR-
ITY HAVING JURISDICTION. THE INFORMATION
STICKER MUST BE FILLED OUT BY THE INSTALLER
AND ADHERED TO THE APPLIANCE AT THE TIME OF
THE CONVERSION. THE QUALIFIED SERVICE AGENCY
PERFORMING THIS WORK ASSUMES RESPONSIBILITY
FOR THIS DERATING.
16
For Canada:
This unit has been tested for installation at high
altitudes in accordance with Canadian test standard
VARIABLE
CAN/CGA-2.17.
REGULATOR TOWER
THE DERATING SHALL BE CARRIED OUT IN ACCOR-
DANCE WITH THE REQUIREMENTS OF THE PROVIN-
CIAL AUTHORITIES HAVING JURISDICTION AND IN
ACCORDANCE WITH THE REQUIREMENTS OF THE
CAN1-B-149.1 AND .2 INSTALLATION CODE.
Derating Procedure
Follow Steps 1-7 of the Fuel Conversion procedure on
pages 15-16 to change the burner orifice for use with
Natural Gas. Use the 3.1 mm orifice supplied with the
High Altitude Adjustment Kit. Instructions are also
included.
and apply the high altitude conversion label pro-
vided to the rating plate on the appliance.
Figure 20 . High Altitude Conversion Label.
INSTALLER: Fill out the appropriate information
THIS STOVE HAS BEEN CONVERTED FOR USE AT AN
ALTITUDE OF: ___________
Orifice Size: __________ Manifold Press. _____
Input Btu/Hr. _________ Fuel Type __________
Date of Conversion ___________