Option Setting; Control Setting - Sanyo VCC-ZM400P Instruction Manual

Colour ccd zoom camera
Hide thumbs Also See for VCC-ZM400P:
Table of Contents

Advertisement

OPTION SETTING

1
MAIN MENU
LANGUAGE
SET
CAMERA ID
OFF
SYNC
INT
PRIVACY MASK
SET
LENS
SET
MIRROR
OFF
VIEW SETTING
1
OPTION
SET
Option settings
• CONTROL setting: This sets whether other peripheral devices
can be used to operate the camera by means of the RS-485
interface or a linked coaxial cable.
• ADDRESS setting: Use this to set the address for this camera
when more than one camera is connected or when other
peripheral devices or a system controller have been connected.
(See p57)
• ALARM setting: This is used for settings related to alarm
input and alarm output. In addition, it is also used to force
selection of COLOR mode or B/W mode when the
DAY/NIGHT setting function is being used. (See p57)

CONTROL setting

1
Use the cursor button (j or l) to move the cursor to
SET for OPTION, then press the SET button.
The OPTION screen will appear.
Note: The PRESET ON setting cannot be used when OPTION
settings are in use.
2
OPTION
CONTROL
485
ADDRESS
0
ALARM
SET
3
RS-485 SETTING
BAUD RATE
19200
TERMINATE
OFF
2
Use the cursor button (j or l) to move the cursor to
485 for CONTROL, use the cursor button (d or c) to
select the device to be operated (e.g. 485), and then
press the SET button.
The RS-485 SETTING screen will appear.
Available settings:
• 485: For operation by the System Controller
• COAX: For operation of device by linked coax cable.
3
Use the cursor button (d or c) to select 19200 for BAUD
RATE.
Available settings: 19200, 9600, 4800, 2400
4
Use the cursor button (j or l) to move the cursor to
TERMINATE, and then use the cursor button (d or c) to
select the terminate setting.
To close the menu screen or return to the previous
screen, select BACK or END for MENU and press the SET
button.
4
RS-485 SETTING
BAUD RATE
19200
TERMINATE
OFF
56

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents