3.3.4.2

Connecting an AC power supply

Note before connecting
NOTICE
Damage to the device in ungrounded supply systems
The device features a safety-certified power cable. Connect the device only to a grounding
socket. Operate the device only on grounded-neutral systems and not on impedance-
grounded systems such as IT networks.
NOTICE
Damage to the device due to connection to the wrong supply voltage
If the local supply voltage is incompatible with the permissible rated voltage for the device,
damage to the equipment may result.
Always make sure that the local supply voltage complies with the permissible rated voltage
for the device.
Regional information
Outside the United States and Canada, in regions with 230 V supply voltage:
If you do not use the safety-certified power cable, use a flexible, double-insulated power
supply cable (no single cables) with the following characteristics:
● At least 18 AWG (0.75 mm
● Grounded safety plug 15 A, 250 V
For USA and Canada:
A CSA or UL-listed power supply cable must be used in the United States and Canada.
Industrial Flat Panel IFP1500, IFP1900, IFP2200
Operating Instructions, 06/2014, A5E31298376-AB
Note
Ensure that the cable set conforms to the respective national safety regulations and is
appropriately labeled.
) conductor cross-section
2
Installing and connecting the device
3.3 Connecting the device
43