Installing the device

3.1

Permitted mounting positions

The device may only be operated in landscape format with a maximum inclination of ±30° to
the vertical.
Permissible ambient temperature: 0 ... 45 °C
3.2

Mounting and connecting the device

This section describes how to mount and connect the device correctly, using stand mounting
as an example. Mounting on a support arm is carried out in the same way. All the work steps
in this chapter have to be carried out sequentially for complete mounting of the device.
Requirement
● A stand with a mechanical interface suitable for the mechanical interface of the device;
see section "Mechanical interface of the device (Page 28)".
– Protective conductor, minimum cross-section of 2.5 mm
– Lines for the external power supply, voltage-free
– Lines for the front operator controls
– All required data lines
● Four hexagon screws M5 according to screw standard ISO 4017, material X5CrNi18-10
The length of the screws have to be dimensioned so that the penetration depth of the
screw thread in the device-side flange lies in the range of 6 to 10 mm.
12
The following lines are routed through the stand:
2
Compact Operating Instructions, 07/2019, A5E35751632-AC
3
IFP1900 INOX PRO