Siemens SIMATIC IFP2200 INOX MT ETH Compact Operating Instructions

Siemens SIMATIC IFP2200 INOX MT ETH Compact Operating Instructions

Hmi devices
Hide thumbs Also See for SIMATIC IFP2200 INOX MT ETH:

Advertisement

Quick Links

SIMATIC
HMI devices
IFP2200 INOX MT ETH
Compact Operating Instructions
Siemens Drives & PLCs
03/2018
A5E42185570-AA
___________________
Preface
___________________
Overview
___________________
Safety instructions and
further information
___________________
Installing and connecting the
device
___________________
Maintenance and care
___________________
Technical specifications
___________________
Technical Support
___________________
List of abbreviations
1
2
3
4
5
A
B

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC IFP2200 INOX MT ETH

  • Page 1 Safety instructions and SIMATIC further information ___________________ Installing and connecting the device HMI devices IFP2200 INOX MT ETH ___________________ Maintenance and care ___________________ Technical specifications Compact Operating Instructions ___________________ Technical Support ___________________ List of abbreviations Siemens Drives & PLCs 03/2018 A5E42185570-AA...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Preface Scope of validity These compact operating instructions apply to the following INOX device: ● SIMATIC IFP2200 INOX MT ETH, article number 6AV7485-6BE00-0AA0 The INOX device is based on the following standard device: ● SIMATIC IFP2200, article number 6AV7863-4MA20-0AA0 With regard to electronics and interfaces, the device is based on the Ethernet monitor IFP2200 ETH with capacitive multi-touch screen and corresponding functionality.
  • Page 4 Applies to System System • Machining center • One or more machines • Device, built-in device, SIMATIC IFP2200 INOX MT ETH • Ethernet monitor Multitouch Ethernet monitor Touch HMI device Device with capacitive multi-touch screen Touch screen Multi-touch screen Touch operation...
  • Page 5: Table Of Contents

    Working with pressure washers ..................25 Working with stainless steel surfaces ................. 27 Clean screen for Touch HMI devices ................. 27 Chemical Resistance ......................28 Calibrate touch screen ....................... 29 Siemens Drives & PLCs IFP2200 INOX MT ETH Compact Operating Instructions, 03/2018, A5E42185570-AA...
  • Page 6 Table of contents Technical specifications ....................... 30 Certificates and approvals ....................30 Dimension drawings ......................33 5.2.1 Dimension drawing 22" device ....................33 5.2.2 Dimension drawing 22" clamping frame ................34 Rating plate ........................35 Technical specifications ......................35 Ambient conditions ......................36 5.5.1 Transport and storage conditions..................36 5.5.2 Operating conditions ......................37 5.5.3...
  • Page 7: Overview

    35°, there are still 10° for safe water runoff. ● Stainless steel surface polished with grain size 240 ● IP66K/P69K degree of protection on front Siemens Drives & PLCs IFP2200 INOX MT ETH Compact Operating Instructions, 03/2018, A5E42185570-AA...
  • Page 8: Scope Of Delivery

    Overview 1.2 Scope of delivery ● Chemical resistance to cleaning agents and disinfectants as described in section "Chemical Resistance (Page 28)". ● Food-grade mounting gasket, exchangeable ● Rear clamping frame for even application pressure of the mounting gasket ● Mounting cutout and interfaces correspond to the standard device. Scope of delivery Depending on the order, the scope of delivery includes: ●...
  • Page 9: Structure Of The Devices

    Overview 1.3 Structure of the devices Structure of the devices Front and side views without Siemens logo ① Recesses for one mounting clip each ② Display with touch screen Interfaces ① Connection for 24 V DC power supply ② Ethernet interface ③...
  • Page 10: Safety Instructions And Further Information

    Safety instructions and further information The general safety instructions in the "Industrial Flat Panel IFP1500, IFP1900, IFP2200, IFP1900 PRO, IFP1900 ETH, IFP2200 ETH" operating instructions apply to all devices with a capacitive multi-touch screen and Ethernet monitors. General safety instructions Installation according to the instructions WARNING The device may only be used in machines which comply with the Machinery Directive...
  • Page 11 7 "Lightning protection and overvoltage protection", which is available on the Internet (https://support.industry.siemens.com/cs/ww/en/view/59193566). The following lightning protection element was used during the testing of the Industrial Flat Panel: Dehn BVT AVD 24" (Order No. 918 422) Siemens Drives & PLCs IFP2200 INOX MT ETH Compact Operating Instructions, 03/2018, A5E42185570-AA...
  • Page 12: Operating The Capacitive Multi-Touch Screen

    Safety instructions and further information 2.2 Operating the capacitive multi-touch screen Operating the capacitive multi-touch screen You operate the multi-touch screen with one or multiple fingers. You can also operate it using gestures with up to five fingers at a time. WARNING Personal injury or property damage due to no earth connection An inadequate earth connection or the lack of one may cause malfunction of the capacitive...
  • Page 13 ● Electromagnetic interference is present that exceeds the specification according to EN 61000-4-2. Once the interference is over, the touch screen is no longer locked. Siemens Drives & PLCs IFP2200 INOX MT ETH Compact Operating Instructions, 03/2018, A5E42185570-AA...
  • Page 14: Installing And Connecting The Device

    Damaged parts A damaged part can cause device malfunctions. Do not install damaged parts. In the case of damaged parts or incomplete delivery, contact your Siemens representative. 3.1.2 Checking the operating conditions Note the following aspects before installing the device: 1.
  • Page 15 Mounting in horizontal format The device is intended for installation in landscape format. A maximum ambient temperature of +45 °C is permissible for vertical installation. Siemens Drives & PLCs IFP2200 INOX MT ETH Compact Operating Instructions, 03/2018, A5E42185570-AA...
  • Page 16: Notes On Installation

    Installing and connecting the device 3.1 Preparing for installation Mounting in vertical format You can also install the device in portrait format. A maximum ambient temperature of +40 °C is permissible for vertical mounting (0° tilt angle); a maximum of +35 °C is permitted for inclined mounting. 3.1.4 Notes on installation Mounting cutout...
  • Page 17: Checking Clearances

    At least 10 mm distance Note Ensure that the maximum ambient temperature is not exceeded when mounting the device in a cabinet and especially in a closed enclosure. Siemens Drives & PLCs IFP2200 INOX MT ETH Compact Operating Instructions, 03/2018, A5E42185570-AA...
  • Page 18: Inserting The Mounting Seal

    Installing and connecting the device 3.2 Inserting the mounting seal Inserting the mounting seal To prevent the mounting seal from being inserted in the wrong direction, it has an asymmetric coding tap. The coding tap is located at the bottom left of all mounting seals of the INOX devices, relative to the rear of the device.
  • Page 19: Mounting The Device

    ● All packaging components and the edge protection tape, if present, have been removed. ● 1 clamping frame ● 1 torque wrench for 1.3 Nm with 2.5 mm with hex socket insert. ● Fasteners: 30 mounting clips Siemens Drives & PLCs IFP2200 INOX MT ETH Compact Operating Instructions, 03/2018, A5E42185570-AA...
  • Page 20 Installing and connecting the device 3.3 Mounting the device Note additional product information included in the scope of delivery, if available. Note Use a tightening torque of 1.3 Nm when tightening the mounting clips with the torque wrench, because the promised degree of protection cannot be guaranteed otherwise. The sealing concept includes a defined seal compression with mechanical end stop.
  • Page 21 10. Tighten all mounting clips once again with the torque wrench and a tightening torque of 1.3 Nm. Removal Proceed in the reverse order for the removal. Dispose of the used mounting seal. Siemens Drives & PLCs IFP2200 INOX MT ETH Compact Operating Instructions, 03/2018, A5E42185570-AA...
  • Page 22: Connecting The Power Supply

    Installing and connecting the device 3.4 Connecting the power supply Connecting the power supply The specifications in the operating instructions "Industrial Flat Panel IFP1500, IFP1900, IFP2200, IFP1900 PRO, IFP1900 ETH, IFP2200 ETH" apply. Refer to the section "Connecting a DC power supply" for information on connecting the power supply. You can operate the device with the following voltage: ●...
  • Page 23: Maintenance And Care

    ● Avoid direct contact of the food with the grouting compound. ● Prevent food adhering to or contacting the grouting compound from returning to the production process. Siemens Drives & PLCs IFP2200 INOX MT ETH Compact Operating Instructions, 03/2018, A5E42185570-AA...
  • Page 24 Maintenance and care 4.1 Cleaning and maintenance General information on cleaning WARNING Danger of explosion when cleaning in hazardous areas When cleaning the front panel in hazardous areas with a dry cloth, static electricity may be discharged. An explosion can result in damage to persons and machines. •...
  • Page 25: Working With Pressure Washers

    • Due to particles of dirt or aerosols swirling up • Due to draining wastewater This is why high-pressure cleaners are generally not recommended for machine and plant cleaning in the hygiene sector. Siemens Drives & PLCs IFP2200 INOX MT ETH Compact Operating Instructions, 03/2018, A5E42185570-AA...
  • Page 26 Maintenance and care 4.2 Working with pressure washers Cleaning guidelines If possible, do not clean the HMI device directly and repeatedly with a pressure washer. ● Use only clean water. ● Cover sensitive areas beforehand. When cleaning with a pressure washer, you need to ensure that you can manually regulate the pressure.
  • Page 27: Working With Stainless Steel Surfaces

    Depending on the software setting, the lockout time can be between 10 and 300 (default setting 30) seconds. The time remaining for the lockout is indicated by a progress bar. Siemens Drives & PLCs IFP2200 INOX MT ETH Compact Operating Instructions, 03/2018, A5E42185570-AA...
  • Page 28: Chemical Resistance

    Maintenance and care 4.5 Chemical Resistance Note Unintentional responses When cleaning the touch screen, touching icons on the screen may cause unintentional reactions in the HMI device. Always open the clean screen or switch off the HMI device before you clean the touch screen while the system is running.
  • Page 29: Calibrate Touch Screen

    Resistance The resistance of the edge grouting to various chemicals has been tested. You can find the list of substances against which the grouting compound has been tested on the Internet (https://support.industry.siemens.com/cs/ww/en/view/39718396) under Customer Support – FAQ. NOTICE Risk of damage to the device When cleaning the device, only use the application concentration specified by the manufacturer of the cleaning agent or the concentration specified in the list.
  • Page 30: Technical Specifications

    Factory Automation DF FA SE R&D Breslauer Str. 5 DE-90766 Fürth, Germany You can download information on the EC Declaration of Conformity, here under the keyword "Declaration of Conformity": IFP certificates (https://support.industry.siemens.com/cs/ww/en/ps/16788/cert) IFP2200 INOX MT ETH Compact Operating Instructions, 03/2018, A5E42185570-AA...
  • Page 31 ● CSA C22.2 No. 61010.1 Approved for use in ● Class I, Division 2, Group A, B, C, D T4 ● Class I, Zone 2, Group IIC T4 Siemens Drives & PLCs IFP2200 INOX MT ETH Compact Operating Instructions, 03/2018, A5E42185570-AA...
  • Page 32 Technical specifications 5.1 Certificates and approvals FCC and Canada Federal This equipment has been tested and found to comply with the limits for a Communications Class A digital device, pursuant to Part 15 of the FCC Rules. These limits Commission are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 33: Dimension Drawings

    Technical specifications 5.2 Dimension drawings Dimension drawings 5.2.1 Dimension drawing 22" device All dimensions in mm Siemens Drives & PLCs IFP2200 INOX MT ETH Compact Operating Instructions, 03/2018, A5E42185570-AA...
  • Page 34: Dimension Drawing 22" Clamping Frame

    Technical specifications 5.2 Dimension drawings 5.2.2 Dimension drawing 22" clamping frame Clamping frame All dimensions in mm IFP2200 INOX MT ETH Compact Operating Instructions, 03/2018, A5E42185570-AA...
  • Page 35: Rating Plate

    MTBF: Operating hours after which the maximum screen brightness is reduced by half compared to the original value. MTBF is increased by using the integrated dimming function, for example, time-controlled via screensaver or centrally via PROFIenergy. Siemens Drives & PLCs IFP2200 INOX MT ETH Compact Operating Instructions, 03/2018, A5E42185570-AA...
  • Page 36: Ambient Conditions

    Technical specifications 5.5 Ambient conditions DC power supply IFP2200 MT ETH Rated voltage 24 V DC, electrically isolated * Power consumption 40 W * Electrical isolation within the safety extra-low voltage circuit The power loss generally corresponds to the specified value for power consumption. Material Component Material...
  • Page 37: Operating Conditions

    Frequency range f in Hz Constant Occasional 10 ... 58 Hz Amplitude 0.0375 mm Amplitude 3.5 mm 58 ... 200 Hz Constant acceleration 0.5 g Constant acceleration 1 g Siemens Drives & PLCs IFP2200 INOX MT ETH Compact Operating Instructions, 03/2018, A5E42185570-AA...
  • Page 38 Technical specifications 5.5 Ambient conditions Testing mechanical ambient conditions The table below provides information on the type and scope of tests for mechanical ambient conditions. Tested for Test standard Comments Vibrations Vibration test in accordance Type of vibration: with IEC 60068, part 2-6 Frequency cycles at a rate of change of (sinusoidal) 1 octave/minute.
  • Page 39: Electromagnetic Compatibility

    HF power applied to Test voltage 10 V, with 80% amplitude modulation of 1 kHz lines and line shields in the 150 kHz to 80 MHz range according IEC 61000-4-6 Siemens Drives & PLCs IFP2200 INOX MT ETH Compact Operating Instructions, 03/2018, A5E42185570-AA...
  • Page 40: Information On Insulation Tests, Protection Class And Degree Of Protection

    Technical specifications 5.5 Ambient conditions Emission of radio interference The following table shows the emitted interference from electromagnetic fields according to EN 61000-6-4, measured at a distance of 10 m. Radiated emission (emitted interference) 1 GHz to 3 GHz < 66 dB peak and < 46 dB average 3 GHz to 6 GHz <...
  • Page 41: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: ● Technical support (https://support.industry.siemens.com) ● Support request form (http://www.siemens.com/automation/support-request) ● After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) ● SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) ● Your local representative (http://www.automation.siemens.com/mcms/aspa-db/en/Pages/default.aspx) ●...
  • Page 42: List Of Abbreviations

    List of abbreviations Direct Current Components and modules endangered by electrostatic discharge Electromagnetic Compatibility European standard Food and Drug Administration Ground High Frequency International Electronic Commission Internet Protocol Light Emitting Diode Thin Film Transistor Underwriter’s Laboratory Universal Serial Bus IFP2200 INOX MT ETH Compact Operating Instructions, 03/2018, A5E42185570-AA...

Table of Contents