Technical information
7.5 Technical specifications
Testing mechanical ambient conditions
The table below provides information on the type and scope of tests for mechanical ambient
conditions.
Tested for
Vibrations
Shock
Climatic ambient conditions
The following table shows the climatic ambient conditions for operation of the device.
Ambient conditions
Temperature:
Vertical mounting
Mounting at an angle
Relative humidity
Atmospheric pressure
Pollutant concentration
1
88
Test standard
Vibration test in accordance
with IEC 60068, part 2–6
(sinusoidal)
Shock test in accordance
with IEC 60068, Part 2 –27
IFP1900 and IFP2200: From 0 to 45° C
Comments
Type of vibration:
Frequency cycles at a rate of change of 1
octave/minute.
5 Hz ≤ f ≤ 8.4 Hz, constant amplitude 3.5 mm
8.4 Hz ≤ f ≤ 150 Hz, constant acceleration 1 g
Vibration duration:
10 frequency cycles per axis in each of the three
mutually vertical axes
Type of shock: Half-sine
Severity of shock:
Peak value 15 g, duration 11 ms
Direction of shock:
3 shocks in ± direction of axis in each of the
three axes vertical to each other
Permitted range
From 0 to 50 °C (horizontal)
From 0 to 40 °C (vertical)
From 0 to 40 °C (horizontal)
From 0 to 35 °C (vertical)
10 to 90%, without condensation
1 080 to 795 hPa
SO
: < 0.5 vpm;
2
Relative humidity <60%, no
condensation
H
S: < 0.1 vpm;
2
Relative humidity <60%, no
condensation
Comments
1
Slope angle max. 35°
Corresponds to an elevation of -
1000 m to 2000 m
Test: 10 cm
/m
3
Test: 1 cm
/m
3
Industrial Flat Panel IFP1500, IFP1900, IFP2200
Operating Instructions, 06/2014, A5E31298376-AB