System Fan - Intel P4304SC2SFEN User Manual

Server system p4000sc family
Table of Contents

Advertisement

Warning
Read all caution and safety
statements in this document
before performing any of the
instructions. Also see the Intel
®
Server Board and Server Chassis
Safety Information document at:
http://www.intel.com/support/
motherboards/server/sb/cs-010770
.htm
for complete safety information.
Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the
property of others. Copyright © 2012, Intel Corporation. All rights reserved.
®
Intel
Server System P4000SC Family Product Configuration
Thermal Operation and Configuration Requirements
One
Intel® Server
To keep the system operating within supported maximum thermal limits, the system must meet the following operating and
Fixed
System
PCI Zone
configuration guidelines:
Fan
(92 x 32 mm)
P4304SC2SFEN
P4304SC2SHDR
P4308SC2MHGC
= Configuration Feature
Thermal Operation and Configuration Requirements
To keep the system operating within supported maximum thermal limits, the system must meet the following operating and configuration
guidelines:
• Ambient in-let temperature cannot exceed 35º C and should not remain at this maximum level for long periods of time. Doing so
may affect long term reliability of the system.
• The CPU-1 processor and CPU heatsink must be installed.
• DIMM Population on CPU-1: Install DIMMs in order; Channels A, B, and C. Start with 1st DIMM slot (blue) on each
channel.
• DIMM Population on CPU-2: Install DIMMs in order; Channels D, E, and F. Start with 1st DIMM slot (blue) on each
channel.
• All hard drive bays must be populated. Hard drive carriers either can be populated with a hard drive or supplied drive blank.
• The air duct must be installed at all times.
• In single power supply configurations, the second power supply bay must have the supplied filler blank installed at all times.
• The system top-cover must be installed at all times.
Warning
Installation and service
of this product to be
performed only by
qualified service personnel
to avoid risk of injury from
electrical shock or energy
hazard.

System Fan

One
Five
4 x 3.5"
Fixed
Hot Swap
CPU Zone
System
Fixed
Fan
Fans
(92 x 32 mm)
(80 x 38 mm)
Caution
Observe normal ESD
[Electrostatic Discharge]
procedures during system
integration to avoid possible
damage to server board and/or
other components.
Hard Drive
Power Supply
4 x 3.5"
8 x 3.5"
One
Hot
Hot
Fixed
Hot Swap
Swap
Swap
550W
460W
ii
Tools Required
Flat Blade
screwdriver
Phillips*
screwdriver
Anti-static
wrist strap
Intel®
Remote
Two
Two
Management
Hot Swap
750W
Module
RMM4 Lite
RMM4