SpectraLink 8020/8030 Wireless Telephone: Administration Guide for SIP
Message
Description
DL Not On Sector
Handset software download files are
incorrect or corrupted.
DO NOT POWER
The handset is in a critical section of
OFF
the software update.
Duplicate IP
The handset has detected another
device with its same IP address.
Erase Failed
Download process failed to erase the
memory in the handset.
Erasing Memory
Handset has determined that a
download should occur and is erasing
the current software from memory.
Files Too Big
Handset software download files are
incorrect or corrupted.
Flash Config Error
Handset internal configuration is
corrupt.
The handset is performing power-on
Initializing ...
initialization.
Initializing SIP
The handset is performing a power-on
initialization of the SIP application.
The phone is initializing its data
structures and attempting to access
the SIP TFTP server and download the
SIP configuration files.
Internal Err. # #
The handset has detected a fault from
which it cannot recover.
Multiple GW Res
More than one SpectraLink 8000 SVP
Server has responded.
92
Action
Download new software from the
Polycom website per Software
Maintenance.
None. Do not remove the Battery Pack
or attempt to power off the phone while
this is displayed. Doing so may require
the handset inoperable.
If using DHCP, check that the DHCP
server is properly configured to avoid
duplicate addresses.
If using Static IP, check that the
handset was assigned a unique
address.
Operation will retry but may eventually
report the error "int. error: 0F" Power
cycle the handset.
None. When the progress bar fills the
display line the erase operation is
complete.
Do not turn the handset off during this
operation.
Download new software from the
Polycom website per Software
Maintenance.
Perform "Restore Defaults" operation
via administrator menus (or re-program
with Configuration Cradle).
None. This is informational only.
None. This is informational only.
Record the error code so it can be
reported.
Turn the handset off then on again.
If error persists, try registering a
different handset to this telephone port.
If error still persists, contact Polycom
Technical Support and report the error.
Caused by two or more handsets
sharing the same IP address. Assign
unique IP addresses to each handset.