Polycom SpectraLink 8020 Administration Manual page 80

Wireless telephone
Hide thumbs Also See for SpectraLink 8020:
Table of Contents

Advertisement

SpectraLink 8020/8030 Wireless Telephone: Administration Guide for SIP
80
All syslog messages will include:
Date and time (to 1/100th of second) since handset power on (The
handset time is set when it is powered on to Jan-1 00:00.00 GMT
adjusted. If it has obtained a time from the network time server,
that time will display instead.)
Handset's MAC address
Handset's IP address
Sequence number
The table below lists the additional items in each message type:
Failed Handoff
(Sent whenever the handset
attempted to handoff, but failed
trying.)
Successful Handoff
Security Error
Call Start
Call End
Failed AP MAC
Failed AP signal strength
Current AP MAC
Current AP signal strength
Failure reason
New AP MAC
New AP signal strength
Old AP MAC
Old AP signal strength
Reason for handoff
Other candidate APs:
MAC
Signal strength
Reason not used
AP MAC
AP signal strength
Security mode
Error details (mode-dependent)
Call type (telephony, OAI, PTT)
AP MAC
AP signal strength
AP MAC
AP signal strength