Insight Display Blue Device Errors - HP BladeSystem c-Class Troubleshooting Manual

Hide thumbs Also See for BladeSystem c-Class:
Table of Contents

Advertisement

CAUTION:
Display shows a firmware update in progress. During this activity, the Insight Display displays the
Firmware Update screen with the Lock icon and the firmware update progress bar.
The Onboard Administrator firmware must be version 2.10 or later to support the c3000 KVM module.
Step
Step 1
Step 2
Procedures: KVM mouse problems
CAUTION:
avoid possible data loss, always secure permission before powering down an enclosure.
CAUTION:
Display shows a firmware update in progress. During this activity, the Insight Display displays the
Firmware Update screen with the Lock icon and the firmware update progress bar.
Step
KVM mouse problems action and verification
Action
Step 1
Access the iLO 2 Remote Console Settings.
Action
Step 2
Set the High Performance Mouse to Disabled or Auto.
Verification
Verify that the mouse tracks properly.

Insight Display blue device errors

For specific component LED definitions and component identification, see "Component identification (on
page 73)."
To avoid data loss, do not remove an Onboard Administrator when the Insight
KVM Linux troubleshooting action and verification
Action
To increase the typematic rate, execute the following command from a Linux shell:
kbdrate -d 1000
As an alternative, disable typematic by executing the following command:
setterm -repeat off
Verification
1
Verify that the following output appears:
Typematic rate set to 11.0 cps (delay = 500 ms)
2
Verify that typing on the KVM keyboard does not generate extra characters.
3
If this corrects the problem, add the command to the Linux startup script.
The repair is complete.
Action
To increase the typematic rate, execute the following command from a Linux X11 GUI
shell:
xset -r rate 1000
As an alternative, disable X11 GUI typematic by executing the following command:
xset -r
Verification
Verify that typing on the KVM keyboard does not generate extra characters. If no extra
characters are present, then add the command to the startup script for X11. The repair is
complete.
Some troubleshooting procedures require powering down an entire enclosure. To
To avoid data loss, do not remove an Onboard Administrator when the Insight
Enclosure troubleshooting 61