Step
Step 18
Step 19

Partner blade troubleshooting

Partner blades are installed in a device bay. The partner blades are either connected to a server blade or
interconnect module in the same enclosure. Partner blades cannot be powered down individually. This
section describes the unique troubleshooting characteristics of those partner blades.
For more information, see the component documentation.
Symptoms: Partner blade errors
Error indication
Insight Display reports error on
suspect partner blade
Partner blade health LED is off
Partner blade health LED is
amber
Partner blade health LED is
green, but another LED on this
partner blade is red
Server blade errors action and verification
Verification
Wait for up to 2 minutes, then check the Insight Display.
If the Insight Display illuminates and the Insight Display buttons operate properly, then
install OA #Y, if present, in OA bay Y to complete the repair.
If the issue still exists, continue to the next step.
Action
Replace the OA tray:
1
Remove OA #X.
2
Remove the OA tray.
3
Install a service spare OA tray.
4
Install OA #X in bay X.
Verification
Wait for up to 2 minutes, and then check the Insight Display.
If the Insight Display illuminates and the Insight Display buttons operate properly, then
install OA #Y, if present, in bay Y to complete the repair.
If the issue still exists, then the OA tray did not fail. Continue to the next step.
Action
Contact an authorized service provider to complete the midplane assembly replacement
(on page 66).
Initial step
For proper installation and support, most
partner blades require a partner server
blade to be installed and powered off
during partner blade installation. If the
partner blade is installed while the
partner server blade is powered up, then
power down the partner server blade
before powering up the partner blade.
Partner blades for interconnect modules
require the interconnect module to be
installed for operation.
Required steps
To correct the issue, follow the
Insight Display steps.
Begin with step 1
To correct the issue, follow the
Insight Display steps.
For LED information, see the partner
blade documentation.
Enclosure troubleshooting 41