Symptoms: Hp Bladesystem C3000 Enclosure Insight Display; Procedures: Hp Bladesystem C3000 Enclosure Insight Display - HP BladeSystem c-Class Troubleshooting Manual

Hide thumbs Also See for BladeSystem c-Class:
Table of Contents

Advertisement

Always read any Warnings and Cautions before beginning the troubleshooting procedure.
Always begin with the step indicated by the symptom.
Perform the operation described in the step, then evaluate the result of that action and perform any
additional procedures as directed. If the issue is not resolved, then continue to the next step.
For specific removal and replacement procedures, see the appropriate enclosure maintenance and service
guide located on the HP website (http://www.hp.com/go/bladesystem/documentation).

Symptoms: HP BladeSystem c3000 Enclosure Insight Display

Symptom
The display screen is off and the
Insight Display buttons do not operate
properly.
The display screen is flashing and the
Insight Display buttons do not operate
properly.

Procedures: HP BladeSystem c3000 Enclosure Insight Display

CAUTION:
avoid possible data loss, always secure permission before powering down an enclosure.
CAUTION:
Display shows a firmware update in progress. During this activity, the Insight Display displays the
Firmware Update screen with the Lock icon and the firmware update progress bar.
Step
Step 1
Step 2
Initial step
Press any Insight Display button to try to
wake up the display. If the Insight
Display health is good, then the Insight
Display powers up automatically.
Press any Insight Display button to stop
the flashing. The Insight Display flashes
when any of the following are true:
If, after inactivity, the health is
degraded or failed
If the UID is on
If a chat message has been sent to
the enclosure
Some troubleshooting procedures require powering down an entire enclosure. To
To avoid data loss, do not remove an Onboard Administrator when the Insight
HP BladeSystem c3000 Enclosure Insight Display action and verification
Action
Check the status of the Onboard Administrator health LED.
Verification
Do one of the following:
If the Onboard Administrator health LED is off, then check the power to the enclosure.
Be sure that the power supplies are installed and operate properly. Complete step 1
again.
If the Onboard Administrator health LED is on, then continue to the next step.
Action
Check the Insight Display to be sure that no firmware updates are in progress.
Verification
Do one of the following:
If the enclosure is performing a firmware update, then wait until the firmware update is
complete. When the update is complete, continue to the next step.
If the enclosure is not performing a firmware update, then continue to the next step.
Required steps
Begin with step 1.
Begin with step 1.
HP BladeSystem Insight Display troubleshooting 17