IBM Network Management Card User Manual page 69

Table of Contents

Advertisement

Table 35. Date and time commands (continued)
Syntax
setDate [option1] [option2]
Options
Date = yyyy/mm/dd
Time = hh:mm:ss
TimeSync = MANUAL | AUTO | NTP
TimeNtp = "xx..xx"
TimeZone = +/-hh:mm
TimeDaylight = 0 | 1
Example
#> getDate timeSync=MANUAL
Comments
Note 1: Setting is write-enabled depending on "TimeSync" status.
Note 2: Setting resolves to the nearest half hour. For example, sending +02:36 results in +02:30, and
sending +02:46 results in +03:00.
Environment commands
Use the environment commands in the following table to configure the optional
environmental monitoring probe.
Table 36. Environment commands
getEnv
Read an environment setting.
Syntax
getEnv [option]
Options
Name
Example
#> getEnv Name
setEnv
Modify an environment setting.
Syntax
setEnv [option]
Options
Name = "xx..xx"
Example
#> setEnv Name="sensor"
getTemp
Read a temperature setting.
Syntax
getTemp [option1] [option2]
Options
Unit | HighThreshold | LowThreshold | Hysteresis | Offset | HighNotify | LowNotify | HighShutdown |
LowShutdown
Example
#> getTemp Unit
setTemp
Modify a temperature setting.
Syntax
setTemp [option1] [option2]
Options
Unit = C | K
HighThreshold = xx
LowThreshold = xx
Hysteresis = xx
Offset = xx
HighNotify = 0 | 1
LowNotify = 0 | 1
HighShutdown = 0 | 1
LowShutdown = 0 | 1
Example
#> setTemp Unit=C
Comments
Note 1: Setting is write-enabled only if the notification is enabled.
(See Note 1)
(See Note 1)
(See Note 2)
(0=No, 1=Yes)
(0 to 5)
(-5 to 5)
(0=No, 1=Yes)
(0=No, 1=Yes)
(0=No, 1=Yes)
(0=No, 1=Yes)
Chapter 4. Using the Telnet, SSH, and CLI
(See Note 1)
(See Note 1)