Omron VARISPEED F7 User Manual page 157

Vector control frequency inverter
Hide thumbs Also See for VARISPEED F7:
Table of Contents

Advertisement

Reference Detection: L4
Param
Name
eter
Num-
Display
ber
Speed agree-
ment detection
level
L4-01
Spd Agree
Level
Speed agree-
ment detection
width
L4-02
Spd Agree
Width
Speed agree-
ment detection
level (+/-)
L4-03
Spd Agree
Lvl+-
5
Speed agree-
ment detection
width (+/-)
L4-04
Spd Agree
Wdth+-
Operation
when fre-
quency refer-
ence is
L4-05
missing
Ref Loss Sel
Frequency ref-
erence value
at frequency
L4-06
reference loss
Fref at Floss
Width of fre-
quency refer-
ence loss
L4-12
FREF Loss
Width
* The given setting range is valid if Heavy Duty is selected (C6-01=0, default setting). If Normal Duty 1 or 2 is selected (C6-01=1 or 2) the setting range will
be 0.0 to 400.0 Hz.
56
5-
Setting
Description
Range
Sets the detection level for the
output frequency detection
function. Effective when a
0.0 to
multi-function digital output is
150.0
set to:
• 3 (f
/ f
agree 1)
out
set
• 4 (Frequency detection 1)
• 5 (Frequency detection 2)
Sets the hysteresis for the out-
put frequency detection func-
tion. Effective when a multi-
function digital input is set to:
0.0 to
• 2 (f
/ f
agree 1)
20.0
ref
out
• 3 (f
/ f
agree 1)
out
set
• 4 (Frequency detection 1)
• 5 (Frequency detection 2)
Sets the detection level for the
output frequency detection
function. Effective when a
-150.0
multi-function digital output is
set to:
+150.0
• 14 (f
/ f
agree 2)
out
set
• 15 (Frequency detetcion 3)
• 16 (Frequency detection 4)
Sets the hysteresis for the out-
put frequency detection func-
tion. Effective when a multi-
function digital input is set to:
0.0 to
• 13 (f
/ f
agree 2)
20.0
ref
out
• 14 (f
/ f
agree 2)
out
set
• 15 (Frequency detection 3)
• 16 (Frequency detection 4)
0: Stop (Operation follows
the frequency reference.)
1: Operation continues at the
frequency, set in parameter
L4-06.
0 or 1
Frequency reference loss
means that the frequency
reference value drops over
90% in 400 ms.
Sets the frequency reference
0.0 to
value when the frequency ref-
100.0%
erence is missing
When the frequency reference
drops by this value within
10 to 80
400ms frequency reference
loss is detected.
Control Methods
Change
Factory
during
Setting
Opera-
V/f
tion
0.0 Hz
No
A
*
2.0 Hz
No
A
to
0.0 Hz
No
A
*
2.0 Hz
No
A
0
No
A
80%
No
A
10%
No
A
MEMO-
V/f
Open
Closed
BUS
with
Loop
Loop
Register
PG
Vector
Vector
A
A
A
499H
A
A
A
49AH
A
A
A
49BH
A
A
A
49CH
A
A
A
49DH
A
A
A
4C2H
A
A
A
4E7H
Page
6-33
6-33
6-33
6-33
6-60
6-60
6-60