Param-
Name
eter
Num-
Display
ber
PG open-cir-
cuit detec-
tion delay
F1-14
time
PGO Detect
Time
Analog Reference Card: F2
Param-
eter
Display
Number
Bi-polar or
uni-polar
input selec-
tion
F2-01
5
AI-14 Input
Sel
38
5-
Description
Used to set the PG disconnec-
tion detection time. PGO will
be detected if the detection
time exceeds the set time.
Name
Description
If an AI-14B analog reference
card is used this parameter sets
the functions for the input
channels 1 to 3.
0: 3-channel individual, the
AI-14B input channels
replace the analog input ter-
minals A1 to A2 of the
inverter (Channel 1: termi-
nal A1, Channel 2: terminal
A2) and adds a third analog
input with Channel 3.
1: 3-channel addition (Addi-
tion values are the fre-
quency reference)
When b1-01 is set to 1 and
F2-01 is set to 0, the multi-
function digital input function
"Option/Inverter selection" can
not be used.
Change
Setting
Factory
during
Range
Setting
Opera-
V/f
tion
0.0 to
2.0 s
No
No
10.0
Change
Setting
Factory
during
Range
Setting
Opera-
V/f
tion
0 or 1
0
No
A
Control Methods
MEMO-
V/f
Open
Closed
BUS
with
Loop
Loop
Register
PG
Vector
Vector
A
No
A
38DH
Control Methods
MEMO
BUS
V/f
Closed
Open
Regis-
with
Loop
Loop
ter
PG
Vector
A
A
A
38FH
Page
6-146
Page
6-149