Pg Speed Control Card Terminals And Specifications; Pg-X2 - Omron VARISPEED F7 User Manual

Vector control frequency inverter
Hide thumbs Also See for VARISPEED F7:
Table of Contents

Advertisement

PG Speed Control Card Terminals and Specifications

PG-B2
The terminal specifications for the PG-B2 are given in the following table.
Terminal
No.
1
Power supply for pulse generator
2
3
Pulse input terminals phase A
TA1
4
5
Pulse input terminals phase B
6
1
Pulse monitor output terminals
phase A
2
TA2
3
Pulse monitor output terminals
phase B
4
TA3
(E)
Shield connection terminal

PG-X2

The terminal specifications for the PG-X2 are given in the following table.
Terminal
No.
1
2
Power supply for pulse generator
3
4
Pulse input terminal phase A (+)
5
Pulse input terminal phase A (–)
TA1
6
Pulse input terminal phase B (+)
7
Pulse input terminal phase B (–)
8
Pulse input terminal phase Z (+)
9
Pulse input terminal phase Z (–)
10
Common terminal inputs
1
Pulse monitor output terminal phase A (+)
2
Pulse monitor output terminal phase A (–)
3
Pulse monitor output terminal phase B (+)
TA2
4
Pulse monitor output terminal phase B (–)
5
Pulse monitor output terminal phase Z (+)
6
Pulse monitor output terminal phase Z (–)
7
Common terminal monitor outputs
TA3
(E)
Shield connection terminal
* 5 VDC and 12 VDC cannot be used at the same time.
Table 2.13 PG-B2 Terminal Specifications
Contents
12 VDC (±5%), 200 mA max.
0 VDC (GND for power supply)
H: +8 to 12 V (max. input frequency: 50 kHz)
GND pulse input phase A
H: +8 to 12 V (max. input frequency: 50 kHz)
GND pulse input phase B
Open collector output, 24 VDC, 30 mA max.
Open collector output, 24 VDC, 30 mA max.
-
Table 2.14 PG-X2 Terminal Specifications
Contents
Specifications
Specifications
12 VDC (±5%), 200 mA max.*
0 VDC (GND for power supply)
5 VDC (±5%), 200 mA max.*
Line driver input (RS422 level)
(maximum input frequency: 300 kHz)
Line driver output (RS422 level output)
2