Output Signal Delay/Hold Function

ON delay/OFF delay times can be set for each output terminal.
All output signals immediately turn ON/OFF when the specified conditions are satisfied.
Depending on the selected signal, chattering may occur. In such a case, use this function to
hold or delay the signal.
Set the output terminals (a total of three terminals corresponding to multi-function outputs P1/
EDM and P2 and multi-function relay outputs MA, MB and MC) one by one. For the output
terminals and the corresponding parameters, refer to the table below.
Output terminal
P1/EDM
P2
Relays (MA, MB, MC)
Parameter No.
C130/C132
C131/C133
C140
C141
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
ON delay time
C130
C132
C140
Function name
Output P1/EDM ON
0.0 to 100.0
Delay Time
Output P1/EDM OFF
0.0 to 100.0
Delay Time
Output RY ON Delay
0.0 to 100.0
Time
Output RY OFF Delay
0.0 to 100.0
Time
5-3 Input/Output Terminals
OFF delay time
C131
C133
C141
Default
Data
setting
0.0
0.0
0.0
0.0
Unit
s
5
s
s
s