7-1 Error Display and Remedial Actions

Warning Display

If the set parameter contradicts other set value, a warning will be displayed and the program
LED indicator will flash.
The table below lists the warnings to be displayed and the conditions in which these warnings
are displayed. If a warning is displayed, change the applicable parameter by referring to the
content of the table. (Issuing a RUN command will not rewrite the parameter to the correct
value automatically).
The last displayed warning is stored in d090.
Warning display
7
7-7
v001
Frequency Upper Limit 1 (A061)
v002
Frequency Lower Limit 1 (A062)
Output Frequency Setting (F001), Multi-
v005
step Speed 1 Reference 0 (A020)
Output Frequency Setting (F001), Multi-
v015
step Speed 1 Reference 0 (A020)
Frequency Lower Limit 1 (A062)
v025
v031
Starting Frequency (b082)
v032
Starting Frequency (b082)
Starting Frequency (b082)
v035
v037
Starting Frequency (b082)
Output Frequency Setting (F001), Multi-
v085
step Speed 1 Reference 0 (A020)
Multi-step Speed References 1 to 15
v086
(A021 to A035)
v091
Free V/f Frequency 7 (b112)
v092
Free V/f Frequency 7 (b112)
Free V/f Frequency 7 (b112)
v095
v201
Frequency Upper Limit 2 (A261)
v202
Frequency Lower Limit 2 (A262)
Output Frequency Setting (F001), Multi-
v205
step Speed 2 Reference 0 (A220)
Output Frequency Setting (F001), Multi-
v215
step Speed 2 Reference 0 (A220)
Frequency Lower Limit 2 (A262)
v225
v231
Starting Frequency (b082)
v232
Starting Frequency (b082)
Starting Frequency (b082)
v235
Warning display condition
Maximum Frequency 1 (A004)
>
Maximum Frequency 1 (A004)
>
Maximum Frequency 1 (A004)
>
Frequency Upper Limit 1 (A061)
>
Output Frequency Setting (F001), Multi-
>
step Speed 1 Reference 0 (A020)
Frequency Upper Limit 1 (A061)
>
Frequency Lower Limit 1 (A062)
>
Output Frequency Setting (F001), Multi-
>
step Speed 1 Reference 0 (A020)
Jogging Frequency (A038)
>
Jump frequency
=
(A063/A065/A067±A064/A066/A068)
=
Frequency Upper Limit 1 (A061)
>
Frequency Lower Limit 1 (A062)
>
Output Frequency Setting (F001), Multi-
>
step Speed 1 Reference 0 (A020)
Maximum Frequency 2 (A204)
>
Maximum Frequency 2 (A204)
>
Maximum Frequency 2 (A204)
>
Frequency Upper Limit 2 (A261)
>
Output Frequency Setting (F001), Multi-
>
step Speed 2 Reference 0 (A220)
Frequency Upper Limit 2 (A261)
>
Frequency Lower Limit 2 (A262)
>
Output Frequency Setting (F001), Multi-
>
step Speed 2 Reference 0 (A220)
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)