Analog Input Filter (FV, FI Sampling)

Helps remove noise in the frequency setting circuit.
If the frequency reference is specified using an external analog signal, a sampling time can be
set for voltage input or current input.
Set a larger data value if stable operation cannot be secured because of noise.
The larger the data value is, the slower the response time. This parameter specifies a filter time
constant for a set value of 1 to 30 (× 2 ms).
When data "31" is selected, a filter time parameter of 500 ms and a hysteresis of ±0.1 Hz are
set.
Parameter
No.
A016
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
Function name
00
Use the FV/FI terminal to switch between
FV (voltage) and FI (current).
FV/FI terminal ON: Current
FV/FI terminal OFF: Voltage
02
Enabled only when 3G3AX-OP01 is
used.
Use the FV/FI terminal to switch between
FV/FI Selection
FV (voltage) and volume.
FV/FI terminal ON: Volume
FV/FI terminal OFF: Voltage
03
Enabled only when 3G3AX-OP01 is
used.
Use the FV/FI terminal to switch between
FI (current) and volume.
FV/FI terminal ON: Volume
FV/FI terminal OFF: Current
Multi-function
16: FV/FI (Analog input switch)
Input Selection
Function name
1. to 30.: Set value × 2 ms filter
Analog Input Filter
31.: Fixed to 500 ms filter
(FV, FI Sampling)
With ±0.1 Hz hysteresis