Parameter
No.
b113
b111
b109
b107
b105
b103
b101
*1.Even when a voltage greater than the Inverter input voltage is set in any one of Free V/f Voltages 1 to
7, the Inverter cannot output such voltage. Use thorough caution to verify that the output characteristic
setting is proper. An improper setting causes overcurrent during acceleration or deceleration, or
vibration of the motor and/or machine.
Output
voltage (V)
V7
V6
0
(Example)
Output
voltage (%)
V7
V6
V5
V4
V1
V2,V3
0
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
Function name
Free V/f Voltage 7 (V7)
Free V/f Voltage 6 (V6)
Free V/f Voltage 5 (V5)
Free V/f Voltage 4 (V4)
0.0 to 800.0
Free V/f Voltage 3 (V3)
Free V/f Voltage 2 (V2)
Free V/f Voltage 1 (V1)
f6
f7
f1
f2
f3
f4
f5
5-5 Settings Relating to Control Method
Default
Data
setting
0.0
Selection of voltage
or motor voltage
that can be output
Output frequency (Hz)
Output frequency (Hz)
f6
f7
Unit
Description
Set output
voltages for
V
each break
*1
point.
5-48
5