4-2 Function Mode
Parameter No. Function name
C160
C161
C162
C163
C164
C165
C166
C169
4
H001
H002
H202
H003 Motor Capacity 1
H203 Motor Capacity 2
H004
H204
H005
H205
4-35
Monitor or data range
Input Terminal 1
Response Time
Input Terminal 2
Response Time
Input Terminal 3
Response Time
Input Terminal 4
0. to 200. (× 2 ms)
Response Time
Input Terminal 5
Response Time
Input Terminal 6
Response Time
Input Terminal 7
Response Time
Multi-step
Speed/Position
0. to 200. (× 10 ms)
Determination
Time
00: Disabled
Auto-tuning
01: Enabled (motor does not
Selection
rotate)
02: Enabled (motor rotates)
Motor Parameter
00: Standard motor
1
parameter
Motor Parameter
01: Auto-tuning parameter
2
0.1/0.2/0.4/0.55/0.75/1.1/1.5/
2.2/3.0/3.7/4.0/5.5/7.5/11.0/
15.0/18.5
Motor Pole
Number 1
2/4/6/8/10
Motor Pole
Number 2
Speed
Response 1
1. to 1000.
Speed
Response 2
Default
Set data
setting
1.
1.
1.
1.
1.
1.
1.
0.
00
00
00
Default
setting
Default
setting
4
4
100.
100.
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
Data can
Data can be
be set
changed
Unit Page
during
during RUN
RUN
no
yes
no
yes
no
yes
no
yes
ms
5-32
no
yes
no
yes
no
yes
no
yes
ms
5-63
no
no
5-146
no
no
no
no
no
no
kW
no
no
kW
5-145
no
no
pole
no
no
yes
yes
yes
yes

Hide quick links: