Life Assessment Monitor [D022]; Position Command Monitor [D029]; Current Position Monitor [D030] - Omron 3G3MX2 User Manual

Sysdrive mx2 series multi-function compact inverter
Hide thumbs Also See for 3G3MX2:
Table of Contents

Advertisement

5-1 Monitor Mode

Life Assessment Monitor [d022]

The LED lighting position indicates the status of life assessment signal.
The following two items can be monitored:
The capacitor service life is calculated every 10 minutes. If the Inverter is turned on/off frequently
within this interval, the capacitor service life cannot be correctly diagnosed.
The cooling fan life assessment function is not available for 1-phase 200V class motors of 0.4 kW
max. and 3-phase 200V class motors of 0.75 kW max., because these motors are not equipped
with a cooling fan.
5

Position Command Monitor [d029]

Position commands can be monitored during simple position control.
For details, refer to "Simple Position Control Function" on page 5-158.
Parameter
d029

Current Position Monitor [d030]

The current position can be monitored during simple position control.
For details, refer to "Simple Position Control Function" on page 5-158.
Parameter
d030
5-9
1: Main circuit board capacitor service life
2: Cooling fan life
ON
OFF
2
1
Function name
No.
Position Command
Monitor
Function name
No.
Current Position
Monitor
Data
−268 (−268435455) to 2684 (268435455)
Displays MSB 4 digits for forward
command. Displays (−) and MSB 3 digits
for reverse command.
(Example) Command value 15600 →
Displays as 1560
Command value −15600 →
Displays as −156
Data
−268 (−268435455) to 2684 (268435455)
Displays MSB 4 digits for forward
position. Displays (−) and MSB 3 digits
for reverse position.
(Example) Current position 1560000 →
Displays as 1560
Current position −1560000 →
Displays as −156
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
Default
Unit
setting
Default
Unit
setting