6-5 Explanation of Each Parameter No.
Response:
No.
1
2
3
4
5
6
7
8
*1. There is no response for broadcasting.
*2. Since the change data comprises both MSB and LSB as a set, make the byte to be an even number
by adding 1, even if the byte which actually needs to be changed is an odd number.
*3. Note that the coil start address is "0006", which is smaller by 1 than the coil number "0007". The coil
number less 1 corresponds to the coil address.
A multi-function input is recognized as ON when the status of either the terminal block input or
communication setting becomes ON.
As for Multi-function Input Monitor (d005), only the terminal block input is monitored.
Refer to "Exceptional Response" on page 6-18 if writing into multiple coils cannot be performed
normally.
6
6-15
Field name
*1
Slave address
Parameter No.
*2
Coil start address (MSB)
*2
Coil start address (LSB)
Number of coils (MSB)
Number of coils (LSB)
CRC-16 (MSB)
CRC-16 (LSB)
Example
(Hex)
01
0F
00
06
00
07
F4
08
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)