Maintenance

This section provides information and procedures for performing projector maintenance. You should
read through this section in its entirety before performing maintenance activities. When you perform
projector maintenance, obey all warnings and precautions.

Inspect Ventilation

Vents and louvers in the projector covers provide ventilation, both for intake and exhaust. Never
block or cover these openings. Do not install the projector near a radiator, heat register, or within an
enclosure. To make sure there is adequate airflow around the projector, keep a minimum clearance of
50cm (19.69") on the left and right sides of the projector.

Check the Coolant Level

HAZARDOUS SUBSTANCE! The coolant used in the projector contains ethylene glycol. Use
caution when handling. DO NOT ingest coolant. Failure to comply results in death or serious
injury.
Use JEFFCOOL E105 coolant only. Using unapproved coolant can damage the projector
damage and void the warranty. Failure to comply could result in death or serious injury.
The liquid cooling system keeps the digital micromirror device (DMD) heat sinks cool. Check the
coolant level every 6 months, by removing the top projector lid. The coolant level should be above
the minimum level indicator. If the liquid cooling system fails, an over-temperature alarm window
appears in the touch panel controller (TPC). The lamp turns off if the projector enters an over-
temperature state for longer than one minute.
When adding coolant, use the refill bottle with the nozzle provided in the Liquid Coolant Fill Service
Kit (P/N: 003-001837-XX). When refilling, use caution not to spill or let any of the coolant drip on or
near the electronics. After filling the reservoir, check the coolant hoses for bends which may restrict
fluid flow.
If coolant drips on electronics or other nearby components, blot the affected area using a dust-free
optical grade tissue. It is recommended you blot a few times, discard the tissue and use a new tissue
to blot the area again. Keep repeating this cycle until the coolant is removed. Then lightly moisten a
new tissue with deionized water and blot the area again. Use a dry tissue to dry the area.
CP2215 User Manual
020-101225-01 Rev. 1 (01-2014)