Front View - AMX Enova DGX 8 Instruction Manual

Enova dgx digital media switchers
Hide thumbs Also See for Enova DGX 8:
Table of Contents

Advertisement

Front View

The enclosure, which is the structural basis of an Enova DGX Switcher, can be controlled using the integrated NetLinx
Central Control Processor, standard front control panel, control software, or an external controller.
For additional information on control options, see page 29.
FIG. 2
Front view of an Enova DGX 32 enclosure
Power Indicator LED on Front of Enclosure
The Power Indicator LED on the front of the enclosure indicates the status of the redundant power system within an
Enova DGX Switcher as follows:
Enova DGX 8/16/32



Enova DGX 64





Important: If two or more power supplies in the Enova DGX 64 are not receiving power, the CPU and the
control panel will continue to operate. However, input and output boards will become inoperable and the
system will not send or receive signals until at least three power supplies resume functional status.
* The LED's response to power functions supersedes the upgrade function.
Instruction Manual – Enova DGX 8/16/32/64 Digital Media Switchers
LCD
Control Dial
Control Keys
Green – both power supplies are powered on
Red – one of the power supplies is not receiving power or has failed
Off – neither power supply is receiving power
Green – all four power supplies are powered on
Flashing Red – one of the power supplies is not receiving power or has failed
Constant Red – two (or three) of the power supplies are not receiving power or have failed
Flashing Green – the system's input/output boards are being upgraded*
Off – none of the power supplies is receiving power
Product Overview and General Specifications
Input Keys
Power Indicator LED
Output Keys
16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents