Front Panel Components

10/100/1000BASE-T Ports (1-8)

The NXA-ENET8-2POE contains 8 RJ-45 ports on the front panel (FIG. 2):
10/100/1000BASE-T Ports (1-8)
FIG. 2
These port (1-8) operate at 10 Mbps or 100 Mbps, half or full duplex, and 1000 Mbps full duplex. Because all ports on the NXA-
ENET8-2POE support automatic MDI/MDI-X operation, you can use straight-through cables for all network connections to PCs or
servers, or to other switches or hubs (see the1000BASE-T Pin Assignments section on page 32).
Each of these ports supports auto-negotiation, so the optimum transmission mode (half or full duplex), and data rate (10,

100, or 1000 Mbps) can be selected automatically. If a device connected to one of these ports does not support auto-
negotiation, the communication mode of that port can be configured manually.
Each port also supports IEEE 802.3x auto-negotiation of flow control, so the NXA-ENET8-2POE can automatically prevent

port buffers from becoming saturated.

SFP Transceiver Slots (9-10)

The Small Form Factor Pluggable (SFP) transceiver slots are independent ports (FIG. 3):
SFP Transceiver Slots
FIG. 3
Refer to the Fiber Optic SFP Devices section on page 28.
The following table shows a list of transceiver types which have been tested with the NXA-ENET8-2POE.
Supported SFP Transceivers
Media Standard
1000BASE-SX
1000BASE-LX
1000BASE-LH
100BASE-FX
1000BASE-T
* Maximum distance may vary for different SFP vendors.
For information on the recommended standards for fiber optic cabling, see the Fiber Standards section on page 33.

Port and System Status LEDs

The NXA-ENET8-2POE includes a LED display panel on the front panel for key system and port indications that simplify installation
and network troubleshooting (FIG. 4):
Power Status LED
Diagnostics Status LED
Port and System Status LEDs
FIG. 4
NXA-ENET8-2POE - Instruction Manual
Fiber Diameter (microns)
50/125
62.5/125
50/125
62.5/125
9/125
9/125
50/125 or 62.5/125
9/125
PoE Status LEDs (ports 1 - 8)
Ethernet Port Status LEDs (ports 1 - 8)
(Link/Activity/Speed)
Wavelength (nm)
Maximum Distance *
850
550 m
850
275 m
1300
550 m
1300
550 m
1300
10 km
1310
35 km
1550
80 km
1300
2 km
1300
20 km
100 m
SPF Port Status LEDs (ports 9 - 10)