If the test switch did not execute correctly:
Check the Power indicator on the front of the enclosure.
Verify the status of the test switch. If status returns as routed correctly, the system established a connection


Check all link and signal connections on the rear of the enclosure(s) to make sure everything is physically set
If applicable – check connections on DGX Fiber Modules (also see "Troubleshooting" in the Instruction
Check all power switches on the source and destination devices to make sure all are turned on.
 Depending on the board type:

FIG. 34
DVI and SC fiber cable adapters



Attempt the switch again.
Instruction Manual – Enova DGX 8/16/32/64 Digital Media Switchers
If it is not illuminated, check the power cords at the enclosure and at the power source.
between the specified input and output connectors within the enclosure.
Control panel: use the Control Dial to scroll to Status. Press the Select Key. Press Output Key 2 (turns
white). If Input Key 1 turns white, the test switch is routed.
BCS commands: enter "SL0O2T". If "SL0O2T(1)" appears, the test switch is routed.
up correctly.
Manual – DGX Transmitters & Receivers) and DXLink Modules/Wallplates (also see "Troubleshooting" in
the Instruction Manual – DXLink™ Twisted Pair Transmitters/Receiver).
Isolate source/destination equipment and cable problems by patching around the router using a cable
adapter to check the overall signal path.
Check the SC fiber connectors to make sure they are fully inserted into the DGX Fiber Module and that no
dust or debris is on the exposed fiber ends of the cable or on the module.
Check the documentation for the DGX Fiber Modules to be sure they are installed correctly. Isolate source
and destination devices using the modules to bypass the enclosure to check the fiber cable and overall
signal path.
Check the documentation for the DXLink™ Transmitters and Receivers to be sure they are installed
correctly. Isolate source and destination devices using the modules to bypass the enclosure to check the
twisted pair cable and overall signal path.
If the switch still does not work, contact technical support (see page 69).