Configuration
3.8.8

Video Loss Event Action (Alarm Out) Setup Screen

52
Siemens Building Technologies
Fire & Security Products
Highlight the Sched box and press the
Set the schedule as described earlier.
Highlight the Camera box and press the
appears. Select the camera number you would like to associate with the camera
that has lost video.
NOTE:
You can associate multiple cameras with a camera.
Highlight the Speed box and select number of images per second you would like
to record from the drop-down menu.
Highlight the Quality box and select the image quality you want to record from
the drop-down menu.
Highlight the Dwell box and set the length of time you would like to record for the
associated video loss.
The DVR can be set to react to video loss differently by activating an internal
buzzer or external alarms.
Fig. 55
Video Loss Event Action (Alarm Out) setup screen.
Highlight the Sched box and press the
Set the schedule as described earlier.
Highlight the Alarm-Out box and select either Beep or the alarm output terminal
that you want to associate with the camera that has lost video.
button. A schedule screen appears.
button. A camera selection screen
button. A schedule screen appears.