6.
Click the Edit Settings button to open the Virtual NetLinx Master Settings dialog (FIG. 34).
FIG. 34
Virtual NetLinx Master Settings dialog
7.
Enter the System number; the default is 1.
8.
Click OK on all open dialogs to save your settings.
9.
Click the OnLine Tree tab in the Workspace window to view the devices on the Virtual System.
10.
Right-click on Empty Device Tree/System and select Refresh System to re-populate the list.
The panel will not appear as a device below the virtual system number (in the Online Tree tab) until
both the system number (default = 1) is entered into the Master Connection section of the System
Settings page and the panel is restarted.



Wireless

1.
When using Wireless Ethernet, press the listed Mode to toggle through the available connection modes:
Connection Modes
Mode Description
None
No connection
Auto
The device connects to the first master that
responds. This setting requires setting the
System Number.
URL
The device connects to the specific IP of a
Master via a TCP connection. This setting
requires setting the Master's IP.
Listen
The device "listens" for the Master to initiate
contact. This setting requires providing the
Master with the device's IP.
2.
Select the Master Port Number to open the keypad and change this value.
The default setting for the port is 1319.
3.
Set the Master Port and select Done.
4.
If you enabled password security on your Master, set the username and password within the device.
5.
Select the blank field Username to open the keyboard.
6.
Set the Username and select Done.
7.
Select the blank field Password to open the keyboard.
8.
Set the Password and select Done.
9.
Press the Back button to return to the Protected Setup page.
MVP-5200i Modero® ViewPoint® Touch Panel with Intercom, 5.2 and 5"
The System Connection status button turns green after a few seconds to indicate an active USB
connection to the PC via the Virtual Master.
If the System Connection icon does not turn green, check the USB connection and communication
settings and refresh the system.
Configuring Communication
Procedures
None
Setting the System Number:
1. Select the System Number to open the keypad.
2. Set your System Number and select Done.
Setting the Master IP:
1. Select the Master IP number to the keyboard.
2. Set the Master IP and select Done.
Confirm that the device IP is on the Master URL
list. Set the Host Name on the device and use it to
locate the device on the Master. Host Name is
particularly useful in the DHCP scenario, where
the IP address can change.