Page Commands

These Page Commands are used in NetLinx Programming Language and are case insensitive.
Page Commands

@APG

Add a specific
popup page to a
specified popup
group.

@CPG

Clear all popup
pages from
specified popup
group.

@DPG

Delete a specific
popup page from
specified popup
group if it exists.

@PDR

Set the popup
location reset flag.

@PHE

Set the hide effect
for the specified
popup page to the
named hide effect.
100
Add the popup page to a group if it does not already exist. If the new popup is added to a
group which has a popup displayed on the current page along with the new pop-up, the
displayed popup will be hidden and the new popup will be displayed.
Syntax:
"'@APG-<popup page name>;<popup group name>'"
Variable:
popup page name = 1 - 50 ASCII characters. Name of the popup page.
popup group name = 1 - 50 ASCII characters. Name of the popup group.
Example:
SEND_COMMAND Panel,"'@APG-Popup1;Group1'"
Adds the popup page 'Popup1' to the popup group 'Group1'.
Syntax:
"'@CPG-<popup group name>'"
Variable:
popup group name = 1 - 50 ASCII characters. Name of the popup group.
Example:
SEND_COMMAND Panel,"'@CPG-Group1'"
Clears all popup pages from the popup group 'Group1'.
Syntax:
"'@DPG-<popup page name>;<popup group name>'"
Variable:
popup page name = 1 - 50 ASCII characters. Name of the popup page.
popup group name = 1 - 50 ASCII characters. Name of the popup group.
Example:
SEND_COMMAND Panel,"'@DPG-Popup1;Group1'"
Deletes the popup page 'Popup1' from the popup group 'Group1'.
If the flag is set, the popup will return to its default location on show instead of its last drag
location.
Syntax:
"'@PDR-<popup page name>;<reset flag>'"
Variable:
popup page name = 1 - 50 ASCII characters. Name of the page the popup is displayed
On.
reset flag = 1 = Enable reset flag
0 = Disable reset flag
Example:
SEND_COMMAND Panel,"'@PDR-Popup1;1'"
Popup1 will return to its default location when turned On.
Syntax:
"'@PHE-<popup page name>;<hide effect name>'"
Variable:
popup page name = 1 - 50 ASCII characters. Name of the page the popup is displayed
On.
hide effect name = Refers to the popup effect names being used.
Example:
SEND_COMMAND Panel,"'@PHE-Popup1;Slide to Left'"
Sets the Popup1 hide effect name to 'Slide to Left'.