The MVP-8400i (FG5965-04/BL) is the ultimate user interface, combining wireless mobility,
table-top functionality, wall/flush mount flexibility and the ability to create a high quality digital
home/office intercom network or to make/receive digital local, long distance and international
telephone calls, simply by adding the AMX SIP Communications Gateway (FG2182-0X).
System integration is simple, and calls sound incredibly clear.
Microphone
Stylus
Docking station interface connector
Pushbuttons (4)
FIG. 1
MVP-8400i (FG5965-04BL) shown
Specifications
MVP-8400i Specifications
Models Available:
• FG5965-04 - Silver
• FG5965-04BL - Black
Dimensions (HWD):
7.17" x 10.47" x 1.34" (18.20 cm x 26.60 cm x 3.40 cm)
Power Requirement
Panel with batteries fully charged or with no batteries:
(without charging):
• Constant current draw: 1.3 A @ 12 VDC
• Startup current draw: 1.9 A @ 12 VDC
• If panel is mounted onto a TDS or WDS, add 0.1 A to the above
figures.
Power Requirement
Panel while charging batteries:
(while charging):
• Constant current draw: 3.3 A @ 12 VDC
• Startup current draw: 3.9 A @ 12 VDC
• If panel is mounted onto a TDS or WDS, add 0.1 A to the above
figures.
Minimum power
PS4.4 Power Supply (FG423-45)
supply required:
- All MVP models are shipped with this power supply.
Power Modes:
• ON: Panel is fully functional.
• STANDBY: Panel uses low power, the LCD/backlight is shutdown,
LEDs still function. Panel resumes the ON mode in ~ 1 second.
• OFF: On-board programs not running, touch screen still powered,
LED not functional. Panel resumes the ON mode in ~ 30 seconds.
Certifications:
• FCC Part 15 Class B and CE
• IEC60950
Battery Duration:
• 8 hours of normal use (25% On state, 25% Standby, and 50% Off).
(using 2 batteries)
• 4 hours of continuous use (continuous On state).
The MVP-8400i ships with two MVP-BP batteries. You must use both
batteries to obtain the duration times given above.
Memory:
128 MB on-board memory
Compact Flash:
2GB or greater (upgradeable to 4GB - see Other AMX Equipment).
Note: AMX may increase Flash size at any time in response to market
availability.
Weight:
• Panel (no batteries): 1.85 lbs (0.84 kg)
• Panel with one battery: 2.25 lbs (1.02 kg)
• Panel with two batteries: 2.65 lbs (1.20 kg)
Screen Properties:
• Screen resolution: 800 x 600 pixels (HV) @ 60 Hz frame frequency
• Aspect ratio: 4 x 3
• Brightness (luminance): 180 cd/m2
• Channel transparency: 8-bit Alpha blending
• Contrast ratio: 350:1
• Display colors: 256K colors (18-bit color depth)
• Dot/pixel pitch: 0.21 mm
• Panel type: TFT Color Active-Matrix
Active Screen Area:
6.71" x 5.03" (17.04cm x 12.78cm)
Viewing Angle:
Vertical: + 60° (up from center) and - 40° (down from center)
Operating/Storage
• Operating Temperature: 0° C (32° F) to 40° C (104° F)
Environments:
• Operating Humidity: 20% - 85% RH
• Storage Temperature: -20° C (-4° F) to 60° C (140° F)
• Storage Humidity: 5% - 85% RH
MVP-8400i
Directional pad w/center select button
Mini-USB connector
Speakers
Power connector
®
8.4" Modero
ViewPoint Touch Panel with Intercom
MVP-8400i Specifications (Cont.)
Included
• Wireless Interface Compact Flash card (CF Type 1) (pre-installed into
Accessories
MVP)
• PS4.4 Power Supply (FG423-44)
• Stylus (pre-installed onto the left side of the unit)
• 2 MVP-BP Power Packs (FG5965-20)
Other AMX
• CB-MVPWDS Conduit Box (FG037-10)
Equipment:
• CC-USB Type A to mini-B programming cable (FG10-5965)
• MVP-BP battery (FG5965-20)
• MVP-KS Kickstand (FG5965-12)
• MVP-STYLUS three pack (FG5965-30)
• MVP-TDS Table Top Docking Station (FG5965-10)
• MVP-WDS Wall Docking Station - Black (FG5965-11)
• MVP-WDS Wall Docking Station - Silver (FG5965-21)
• MVP-WDS-SK Silver Conversion Kit (FG5965-22)
• Upgrade Compactflash (pre-programmed with firmware):
NXA-CFTP4G, 4GB Compactflash Upgrade (FG2116-08)
Caution: There are particular operations, such as upgrading the Compactflash card and
replacing/installing the NXA-WC80211GCF Wireless Compact Flash Card, that require
opening the MVP's outer housing to access internal components (as described in the
Modero ViewPoint Touch Panels Operation/Reference Guide). When opening the MVP panel
housing to access internal components, be careful not to damage or disconnect the wireless
compact flash card antenna, which is mounted to the inside of the rear housing.

Connections and Wiring

The PS4.4 Power Supply (with barrel connector) provides power to the MVP-8400 either
directly (via the power connector located on the lower right-side of the panel) or indirectly (by
routing incoming power through the Docking Station's MVP Interface Connector).
Once the MVP is connected to a docking station; charging priority is first given to any
MVP-BP battery packs found within the MVP-8400 and then to any other batteries inserted
into the docking station's battery charging compartments.
WARNING: Although firmware upgrades can be done over wireless Ethernet; it is strongly
recommended that firmware KIT files be transferred over a direct USB connection and only
when the panel is connected to a power supply. If battery power or wireless connection fails
during a firmware upgrade, the panel flash file system may become corrupted.

Setup Pages

The panel is equipped with setup pages that allow you to set and configure various features
on the panel. Consult the MVP-7500/8400 Modero ViewPoint Touch Panels Operation/
Reference guide for detailed information on the Setup pages.
Accessing the Setup and Protected Setup Pages
1.
Press down and hold both the bottom, left pushbutton and down on the directional pad
simultaneously for 3-5 seconds. This opens the Setup page.
Setup Page Access buttons
FIG. 2
Setup Page Access buttons
2.
Press the Protected Setup button. This invokes a keypad for entry of the password to
allow access to the Protected Setup page.
3.
Enter the panel password into the keypad (default is 1988) and select Done to access
the Protected Setup page.
Setting the Panel's Device Number
In the Protected Setup page:
1.
Press the Device Number field to open the Device Number keypad.
Enter a unique Device Number assignment for the panel, and press Done to return to
the Protected Setup page.
2.
Press Reboot to reboot the panel, and apply the new Device Number.

Configuring a Wireless Network Access

When working with a wireless card, the first step is to configure wireless communication
parameters within the Wireless Settings page. This page only configures the card to
communicate to a target WAP (such as the NXA-WAP200G), it is still necessary to tell the
panel which Master it should be communicating with. This "pointing to a Master" is done via
the System Settings page where you configure the IP Address, System Number and
Username/Password information assigned to the target Master.
Step 1: Configure the Panel's Wireless IP Settings
The first step to successfully setting up your internal wireless card is to configure the IP
Settings section on the Wireless Settings page. The options on this page configure the
communication parameters from the MVP panel to the web.

Installation Guide

Press / hold both for
3-5 seconds to access
the Setup pages
Press / hold both for
6 seconds to access
the Calibration page

Advertisement

loading

Summary of Contents for AMX MVP-8400i

  • Page 1: Installation Guide

    Compact Flash: 2GB or greater (upgradeable to 4GB - see Other AMX Equipment). Setting the Panel’s Device Number Note: AMX may increase Flash size at any time in response to market In the Protected Setup page: availability. Press the Device Number field to open the Device Number keypad.
  • Page 2: Touch Panel Calibration

    ©2010 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX. AMX reserves the right to alter specifications without notice at any time. 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com...