7.
In the Available Connections section, click on the IP address for the touch panel to select it.
8.
In the Virtual NetLinx Master Settings dialog box, click OK to close the box.
9.
In the Communications Settings dialog box, click OK to close the box.
10.
In the Master Communications Settings dialog box, click OK to save your settings and return to the main
NetLinx Studio application.
11.
Click the OnLine Tree tab in the Workspace window to view the devices on the Virtual System. The
default System value is 1.
12.
Right-click on the Empty Device Tree/System entry and select Refresh System to re-populate the list.
The panel will not appear as a device below the virtual system number, in the Online
Tree tab, until both the system number used in step 14 for the Virtual NetLinx Master
is entered into the Master Connection section of the System Settings page and the
panel is restarted.
13.
The OnLine Tree should now display the connection to the device. The Connection Status Icon on the
device may take up to five seconds to register the connection.

Step 3: Confirm and Upgrade the firmware via the USB port

Use the CC-USB Type-A to Mini-B 5-wire programming cable to provide communication between the mini-
USB Program port on the touch panel and the PC. This method of communication is used to transfer firmware
Kit files and TPD4 touch panel files.
A mini-USB connection is only detected after it is installed onto an active panel.
1.
Verify that the direct USB connection (Type-A on the panel to mini-USB on the panel) is configured
properly, using the steps outlined in the previous two sections.
2.
With the panel already configured for USB communication and the Virtual Master setup within NetLinx
Studio, refresh the Online Tree pane.
3.
After the Communication Verification dialog window verifies active communication between the Virtual
Master and the panel, click the OnLine Tree tab in the Workspace window (FIG. 74) to view the devices
on the Virtual System. The default System value is 1.
4.
Right-click on the System entry (FIG. 74) and select Refresh System to re-populate the list. Verify the
panel appears in the OnLine Tree tab of the Workspace window.