Dell PowerEdge C8220X Hardware Owner's Manual page 38

Servers
Hide thumbs Also See for PowerEdge C8220X:
Table of Contents

Advertisement

Error
Error Message
Code
002Fh No Microcode
Be Updated
8012h
SATA 0 Device
Not Found
8013h
SATA 1 Device
Not Found
8014h
SATA 2 Device
Not Found
8015h
SATA 3 Device
Not Found
38
About Your System
Response Error Cause
Pause
Processor
microcode load
failed
Pause
SATA 0 device
not found
Pause
SATA 1 device
not found
Pause
SATA 2 device
not found
Pause
SATA 3 device
not found
Corrective Actions
Ensure that your processors
match and conform to the
type described in the
processor technical
specifications outlined in
your system's Getting Started
Guide.
Check if the SATA port 0 is
enabled. See "SATA
Configuration" on page 88.
Install a SATA device to SATA
port 0.
If the problem persists, see
"Getting Help" on page 369.
Check if the SATA port1 is
enabled. See "SATA
Configuration" on page 88.
Install a SATA device to SATA
port 1.
If the problem persists, see
"Getting Help" on page 369.
Check if the SATA port 2 is
enabled. See "SATA
Configuration" on page 88.
Install a SATA device to SATA
port 2.
If the problem persists, see
"Getting Help" on page 369.
Check if the SATA port 3 is
enabled. See "SATA
Configuration" on page 88.
Install a SATA device to SATA
port 3.
If the problem persists, see
"Getting Help" on page 369.