9 Close the sled. See "Installing the Front and Back Sled Covers" on
page 180 or "Installing the Sled Cover" on page 183.
10 Reinstall the sled into the enclosure. See "Installing a Sled" on page 156.
11 Turn on the sled and attached peripherals.
12 If the problem persists, turn off the sled and attached peripherals.
13 Remove the sled from the enclosure. See "Removing a Sled" on page 155.
14 Open the sled. See "Removing the Front and Back Sled Covers" on
page 176 or "Removing the Sled Cover" on page 181.
15 Remove the cooling shroud. See "Removing the Cooling Shroud" on
page 276.
16 Remove processor 2. See "Removing a Processor" on page 283.
17 Replace the cooling shroud. See "Installing the Cooling Shroud" on
page 277.
18 Close the sled. See "Installing the Front and Back Sled Covers" on
page 180 or "Installing the Sled Cover" on page 183.
19 Reinstall the sled into the enclosure. See "Installing a Sled" on page 156.
20 Turn on the sled and attached peripherals.
If the problem persists, the processor is faulty. See "Getting Help" on
page 369.
21 Turn off the sled and attached peripherals.
22 Remove the sled from the enclosure. See "Removing a Sled" on page 155.
23 Open the sled. See "Removing the Front and Back Sled Covers" on
page 176 or "Removing the Sled Cover" on page 181.
24 Remove the cooling shroud. See "Removing the Cooling Shroud" on
page 276.
25 Replace processor 1 with processor 2. See "Installing a Processor" on
page 285.
26 Close the sled. See "Installing the Front and Back Sled Covers" on
page 180 or "Installing the Sled Cover" on page 183.
27 Repeat step 16 through step 10.
If you have tested both the processors and the problem persists, the system
board is faulty. See "Getting Help" on page 369.
Troubleshooting
345