9.8 SUPPLY OF COMBUSTION AIR 
In  Canada,  wood  inserts  are  not  required  to  have  a  supply  of  combustion  air  from  outdoors 
because  research  has  shown  that  these  supplies  do  not  give  protection  against  house 
depressurization and may fail to supply combustion air during windy weather. However, to protect 
against  the  risk  of  smoke  spillage  due  to  house  depressurization,  a  carbon  monoxide  (CO) 
detector/alarm  is  required  in  the  room  in  which  the  insert  is  installed.  The  CO  detector  will 
provide warning if for any reason the wood insert fails to function correctly. 
9.8.1 AIR SUPPLY IN CONVENTIONAL HOUSES 
The  safest  and  most  reliable  supply  of  combustion  air  for  your  wood  insert  is  from  the  room  in 
which it is installed. Room air is already preheated so it will not chill the fire, and its availability is 
not affected by wind pressures on the house. Contrary to commonly expressed concerns, almost 
all  tightly‐sealed  new  houses  have  enough  natural  leakage  to  provide  the  small  amount  of  air 
needed  by  the  insert.  The  only  case  in  which  the  wood  insert  may  not  have  adequate  access  to 
combustion air is if the operation of a powerful exhaust device (such as a kitchen range exhaust) 
causes the pressure in the house to become negative relative to outdoors.  
If  you  do  install  an  air  supply  through  the  wall  of  the  house,  be  aware  that  its  pressure  can  be 
affected  during  windy  weather.  If  you  notice  changes  in  wood  insert  performance  in  windy 
weather, and in particular if smoke puffs from the insert, you should disconnect the outdoor air 
duct from the insert and remove the duct. In some windy conditions, negative pressure at the duct 
weatherhood  outside  the  house  wall  may  draw  hot  exhaust  gases  from  the  insert  backwards 
through the duct to outdoors. Check the outdoor air duct for soot deposits when the full system is 
cleaned and inspected at least once each year. 