  2000 Insert Installation and Operation Manual 
7 SAFETY INFORMATION 
7.1 SUMMARY OF INSTALLATION CAUTIONS AND WARNINGS 
THE  INFORMATION  GIVEN  ON  THE  CERTIFICATION  LABEL  AFFIXED  TO  THE  APPLIANCE 
ALWAYS  OVERRIDES  THE  INFORMATION  PUBLISHED,  IN  ANY  OTHER  MEDIA  (OWNER'S 
MANUAL, CATALOGUES, FLYERS, MAGAZINES AND/OR WEB SITES). 
MIXING  OF  APPLIANCE  COMPONENTS  FROM  DIFFERENT  SOURCES  OR  MODIFYING 
COMPONENTS MAY RESULT IN HAZARDOUS CONDTIONS. WHERE ANY SUCH CHANGES ARE 
PLANNED, STOVE BUILDER INTERNATIONAL INC. SHOULD BE CONTACTED IN ADVANCE.  
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE 
TESTING AUTHORITY VIOLATES CSA B365 (CANADA), AND ANSI NFPA 211 (USA).  
CONNECT  THIS  INSERT  ONLY  TO  A  LISTED  STAINLESS  STEEL  CHIMNEY  LINER  FOR  USE  WITH 
SOLID FUEL. 
IF REQUIRED, A SUPPLY OF COMBUSTION AIR SHALL BE PROVIDED TO THE ROOM. 
DO NOT CONNECT TO OR USE IN CONJUNCTION WITH  ANY AIR DISTRIBUTION DUCTWORK 
UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATION. 
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. 
THE INSERT AND ITS STAINLESS STEEL CHIMNEY LINER ARE TO BE INSTALLED ONLY WITHIN A 
LINED  MASONRY  CHIMNEY  AND  MASONRY  FIREPLACE  CONFORMING  TO  BUILDING  CODES 
FOR  USE  WITH  SOLID  FUEL.    DO  NOT  REMOVE  BRICKS  OR  MORTAR  FROM  THE  EXISTING 
FIREPLACE WHEN INSTALLING THE INSERT. 
7.2 REGULATIONS COVERING INSERT INSTALLATION 
When installed and operated as described in these instructions, the Osburn 2000‐I wood insert is 
suitable  for  use  in  residential  installations.  The  Osburn  2000‐I  wood  insert  is  not  intended  for 
installation in a bedroom. 
In  Canada,  the  CSA  B365  Installation  Code  for Solid  Fuel Burning  Appliances  and  Equipment  and 
the CSA C22.1 Canadian National Electrical Code are to be followed in the absence of local code 
requirements. In the USA, the ANSI NFPA 211 Standard for Chimneys, Fireplaces, Vents and Solid 
Fuel‐Burning Appliances and the ANSI NFPA 70 National Electrical Code are to be followed in the 
absence of local code requirements. 
This insert must be installed with a continuous chimney liner of 6" diameter extending from the 
insert to the top of the chimney. The chimney liner must conform to the Class 3 requirements of 
CAN/ULC‐S635,  Standard  for  Lining  Systems  for  Existing  Masonry  or  Factory‐built  Chimneys  and 
Vents, or CAN/ULC‐S640, Standard for Lining Systems for New Masonry Chimneys. 
NOTE:    The Insert is not approved for use with a so‐called "positive flue connection" to the clay 
tile of a masonry chimney. 