8 CLEARANCES TO COMBUSTIBLE MATERIAL

The clearances shown in this section have been determined by test according to procedures set 
out in safety standards ULC S628 (Canada), UL1482 (U.S.A.) and UL737 (U.S.A.). When the insert is 
installed  so  that  its  surfaces  are  at  or  beyond  the  minimum  clearances  specified,  combustible 
surfaces will not overheat under normal and even abnormal operating conditions.  
No part of the insert may be located closer to combustibles than the minimum clearance figures 
given. 
 
8.1 LOCATION OF THE CERTIFICATION LABEL 
Since the information given on the certification label attached to the appliance always overrides 
the  information  published  in  any  other  media  (owner's  manual,  catalogues,  flyers,  magazines 
and/or web sites), it is important to refer to it in order to have a safe and compliant installation. In 
addition, you will find information about your insert (model, serial number, etc.). You can find the 
certification label on the side, towards the front of the outside of the air jacket of the insert. 
To  access  the  certification  label,  the  faceplate  may  need  to  be  removed.  Therefore,  we 
recommend  that  you  note  the  insert's  serial  number  on  this  manual,  since  it  will  be  needed  to 
precisely  identify  the  version  of  the  appliance  in  the  event  you  require  replacement  parts  or 
technical assistance. 
 
8.2 THE MASONRY FIREPLACE THROAT DAMPER 
If the fireplace's draft control system is to remain in the masonry fireplace, it must be locked open 
for  access  of  the  chimney  liner  or  removed  entirely.  If  you  remove  draft  control  system  from  the 
masonry hearth, you will need to install the metal plate (27009), supplied with the owner's manual 
kit, indicating that the  masonry hearth has  been modified.  It must be secured  inside the masonry 
hearth, in a visible place and easy to locate. 
 
 