Compliance Of A Combustible Mantel Shelf - Osburn 2000 Installation And Operation Manual

Hide thumbs Also See for 2000:
Table of Contents

Advertisement

  2000 Insert Installation and Operation Manual 
8.3 COMPLIANCE OF A COMBUSTIBLE MANTEL SHELF 
To ensure compliance of an existing mantel shelf or to install a combustible mantel shelf, refer to 
table and figure below. For example, a mantel shelf with a 8'' depth (203 mm) ((X) value) must be 
installed at least 22" (559 mm) ((I) value) above the top of the insert (see figure below). Different 
mantel shelf dimensions are listed in the following table. However, no combustible mantel shelf 
can be installed at less than 22" (559 mm) above the top of the insert.  If the depth of the mantel 
shelf is not listed in the table below, add 14" (356 mm) to the depth of your mantel shelf to obtain 
the safe positioning of your mantel shelf. For example, for a 9" (229 mm) mantel shelf, the safe 
positioning would be 23" (584 mm) above the top of the insert (14" (356 mm) + 9" (229 mm)). 
 
 
MAXIMUM MANTEL 
SHELF DIMENSION (X) 
8" / 203 mm 
10" / 254 mm 
12" / 305mm 
 
Note that you can reduce the mantel shelf clearance 
with  the  use  of  a  heat  shield,  sold  separately.  See 
Appendix  5:  Heat  Shield  Installation  (AC01317)  for 
detail. 
 
 
 
32  _ _____________________________________________________________________________   
MANTEL SHELF 
CLEARANCES 
(I) 
22" (559 mm) 
24" (610 mm) 
26" (660 mm) 
 
 
 
 