Advanced Operation
The 4x4 Seamless Matrix for HDMI supports IP-based control using Telnet, UDP, or the
built-in Web-based GUI. To set up IP control, the network settings for the 4x4 Seamless
Matrix for HDMI must be configured via RS-232. The default network settings for the matrix
are as follows:
Description
IP Address
Subnet
Gateway
HTTP Port
1.
Connect an RS-232 cable from the PC to the 4x4 Seamless Matrix for HDMI.
Also make sure that an Ethernet cable is connected between the matrix and the
network.
2.
Launch a terminal emulation program (e.g. HyperTerminal) and use the RS-232
settings listed on the previous page.
NOTE: Depending upon the network, all related IP, Telnet, and
UDP settings will need to be assigned. Consult your network
administrator to obtain the proper settings.
3.
Set the IP address for the matrix using the
4.
Set the subnet mask using the
5.
Set the gateway (router) IP address using the
6.
Set the Telnet listening port using the
7.
Set the HTTP listening port using the
8.
Set the UDP remote IP address for the matrix using the
command.
9.
Set the UDP listening port for the matrix using the
10. Set the UDP remote port for the matrix using the
command.
11. Reboot the matrix to apply all changes, then type the IP address that was
specified in step 3, in a Web browser to access the Web GUI. Use the same IP
address to Telnet to the matrix.

IP / UDP Configuration

IP Address / Port
192.168.1.72
255.255.255.0
192.168.1.254
80
#set_netmask
page | 55
RS-232 and IP Configuration
Description
UDP Port
Local UDP Port
Remote UDP IP
Remote UDP Port 50008
#set_ipadd
command.
command.
#set_gateway
#set_telnet_port
#set_http_port
command.
#set_udp_remote_ip
#set_udp_port
#set_udp_remote_port
IP Address / Port
23
50007
192.168.1.255
command.
command.
command.