RS-232/USB-Com Interfaces
ACK NAK Timeout Value
This option specifies the amount of time the reader waits for an ACK character from the host
following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15
seconds) in 200ms increments. A selection of 0 disables the timeout.
To set this value:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 200 (setting is in 200ms increments). Pad the result with
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
4. Scan the barcode: SELECT ACK NAK TIMEOUT VALUE SETTING.
5. Scan the appropriate two digits from the keypad in
NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
This completes the procedure. See Table
Table 10. ACK NAK Timeout Value Setting Examples
STEP
ACTION
1
Desired Setting
2
Divide by 200
3
4
Scan Two Characters From
5
Appendix E, Keypad
6
88
leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
Mode.
the duration which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
If you make a mistake before the last character, scan the CANCEL
barcode to abort and not save the entry string. You can then start
again at the beginning.
Mode.
200ms
01
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT ACK NAK TIMEOUT VALUE SETTING
'0' and '1'
Scan ENTER/EXIT PROGRAMMING MODE
Appendix E,
10
for some examples of how to set this feature.
EXAMPLES
5200ms (5.2
1,000ms (1 sec.)
sec.)
05
26
'0' and '5'
'2' and '6'
Gryphon™ I GD4100/GM4100
Keypad, that represent
15,000ms (1 sec.)
75
'7' and '5'