Symbologies
Industrial 2 of 5 Set Length 2 — cont.
4. Scan the appropriate two digits from the keypad in the Keypad Appendix that represent
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
This completes the procedure. See the table below for some examples of how to set this feature.
Table 32. Industrial 2 of 5 Length 2 Setting Examples
STEP
ACTION
1
Desired Setting
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT INDUSTRIAL 2 OF 5 LENGTH 2 SETTING
Scan Two Characters From the
4
Keypad Appendix
5
Scan ENTER/EXIT PROGRAMMING MODE
Select Industrial 2 of5 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not
save the entry string. You can then start again at the beginning.
280
the length setting which was determined in the steps above. You will hear a two-beep indi-
cation after the last character.
If you make a mistake, before the last character scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
NOTE
Mode.
00 (Ignore This
Length)
'0' and '0'
ENTER/EXIT PROGRAMMING MODE
DEFAULT
EXAMPLES
07 Characters
'0' and '7'
50 = Length 2 is 50 Characters
15 Characters
50 Characters
'1' and '5'
'5' AND '0'
CANCEL