 Trunking
l
 Port Mirroring
l
 VLANs
l
 
For example, VLANs can be configured from ports belonging to different stack members, or configure port mirroring from a second stack member to a third
stack member. Applications running in a stacking configuration are centralized. For example, the Spanning Tree Protocol for the entire stack runs on the master
unit. Device software is downloaded separately for each stack member.
 
PowerConnect 3324/3348 stacking architecture provides dynamic learning for the stacking topology, while detecting and reconfiguring the ports with minimal
operational impact in the event of:
 Unit Failure
l
 Inter-unit Link Loss
l
 Unit Insertion
l
 Removal of a Stacking Unit
l
 

Stack Members and Unit ID

 
The stacking operation mode is determined during the Boot process.
 
PowerConnect 3324/3348 units are shipped with a default Unit ID of one. The Unit ID is essential to the stacking configuration. If a stack member reboots
without a stacking module, the device operates as a stand-alone until the device is reset. If a PowerConnect 3324/3348 unit is operating as a stand-alone
unit, all stacking LEDs are off. The Unit ID is not erased and remains valid if the unit is reconnected to a stack.
 
NOTE:
The stacking module must be inserted into port G2 for the stack to operate. If the stacking module is inserted in port G1, a warning message is
displayed on the console.
 
When the master unit boots or when inserting or removing a stack member, the master unit initiates a stacking discover process. If two members are
discovered with the same Unit ID, or a master unit is not found, the entire stack cannot function. The stacking LED remains red.
 

Configuration Handling

 
In a PowerConnect 3324/3348 operative stack, the stack master is responsible for the stack configuration. Each stack member does not have a separate
configuration file. Each port in the stack has a specific Unit ID/port type and port number, which is part of both the configuration commands and the
configuration files. Configuration files are managed only from the PowerConnect 3324/3348 stack master, including:
 Saving to the FLASH.
l
 Uploading Configuration files to an external TFTP Server.
l
 Downloading Configuration files from an external TFTP Server.
l
 
NOTE:
Stack configuration for all configured ports is saved, even if the stack is reset and/or the ports are no longer present.
 
Configuration files are changed only through explicit user configuration. In addition, Configuration files are not automatically modified when:
 Units are added.
l
 Units are removed.
l
 Units are reassigned Unit IDs.
l
 Units toggle between stacking mode and stand-alone mode.
l
 
Each time the system reboots, the stored configuration is written in the Startup Configuration file.
 
If a PowerConnect 3324/3348 stack member is removed from the stack, and then replaced with the same Unit ID, the stack member is configured with the
original device configuration.
 