1. Connect the PowerConnect 3324/3348 device to the RS232 interface of a computer operating as an ASCII terminal.
2. Set the ASCII terminal with the following settings and select the appropriate COM port (In this example using Windows Hyper Terminal application):
NOTE:
9600 is the default baud rate for new device. If using 9600 baud rate does not result in viewing the device terminal, try another baud rate
setting (the device may be set at a different baud rate).
3. Use an F2F Null Modem cable to connect the PC running the ASCII terminal to the device.
4. Insert the device's power cord into an electrical outlet to power up the device. The following screen is displayed:
**************************************************
***************** SYSTEM RESET *****************
**************************************************
Booting...
------ Performing the Power-On Self Test (POST( ------
UART Channel Loopback Test........................PASS
Testing the System Cache..........................PASS
Testing the System SDRAM..........................PASS
Boot1 Checksum Test...............................PASS
Boot2 Checksum Test...............................PASS