Installing the PowerConnect 3324/3348 Switch
Dell™ PowerConnect™ 3324/3348 User's Guide
  Installation Precautions
  Site Requirements
  Unpacking and Installation
  Cable, Port, and Pinout Information
 

Installation Precautions

 
CAUTION:
The rack or cabinet housing the switch should be adequately secured to prevent it from becoming unstable and/or falling over.
 
CAUTION:
Ensure the power source circuits are properly grounded.
 
CAUTION:
Observe and follow service markings. Do not service any product except as explained in your system documentation. Opening or
removing covers marked with a triangular symbol with a lighting bolt may cause electrical shock. These components are to be serviced by trained
service technicians only.
 
CAUTION:
Ensure the power cable, extension cable, and/or plug is not damaged.
 
CAUTION:
Ensure the product is not exposed to water.
 
CAUTION:
Do not push foreign objects into the device, as it may cause a fire or electric shock.
 
CAUTION:
Allow the product to cool before removing covers or touching internal equipment.
 
CAUTION:
Ensure the switch does not overload the power circuits, wiring, and over-current protection. To determine the possibility of
overloading the supply circuits, add together the ampere ratings of all switches installed on the same circuit as the switch. Compare this total
with the rating limit for the circuit. The maximum ampere ratings are usually printed on the switch, near their AC power connectors.
 
NOTICE:
Ensure the device is not exposed to radiators and/or heat sources.
 
NOTICE:
Ensure the cooling vents are not blocked.
 
NOTICE:
Use the device only with approved equipment.
 
NOTICE:
Do not install the switch in an environment where the operating ambient temperature might exceed 40ºC (122ºF).
 
NOTICE:
Ensure the air flow around the front, sides, and back of the switch is not restricted.
 

Site Requirements

 
Dell™ PowerConnect™ 3324/3348 series equipment can be mounted in a standard 19-inch equipment rack or placed on a table. Before installing the unit,
verify that the location chosen for installation meets the site requirements described below.
 General—Ensure that the power supply is correctly installed.
l
 Power—The unit is installed within 1.5 m (5 feet) of a grounded, easily accessible outlet 100-250 VAC, 50-60 Hz. It is preferred that two separate
l
power supplies are provided, for example, a UPS and a separated phased supply.
 Clearance—There is adequate frontal clearance for operator access. Allow clearance for cabling, power connections, and ventilation.
l
 Cabling—Cabling is routed to avoid sources of electrical noise such as radio transmitters, broadcast amplifiers, power lines, and fluorescent lighting
l
fixtures.
 Ambient Requirements—The ambient unit operating temperature range is 0 to 40ºC (32 to 122ºF) at a relative humidity of up to 95%, non-condensing.
l
Verify that water or moisture cannot enter the case of the unit.
 