2.
OTHER SERVICE FUNCTIONS
2.1
Resetting the Periodical Replacement Parts Life
2.1.1 Resetting the Life Counter of the Belt Unit
<Function>
This function allows you to reset the page counter of the belt unit and increase the number of
replacement times by one.
<Operating Procedure>
(1) Press the 3 and 9 buttons at the same time in the ready state.
The "Reset Menu / Drum" will appear on the LCD.
(2) Press the
(3) Press the OK button.
The "Belt unit / 1. Reset 2. Exit" will appear on the LCD.
(4) Press the 1 button when resetting the page counter of the belt unit. Press the 2 button if
not resetting.
(5) The "Belt unit / Accepted" will appear on the LCD if pressing the 1 button. The page
counter of the belt unit is reset, and the number of replacement times is increased by one.
Then, the machine returns to the ready state.
If pressing the 2 button, the machine returns to the Belt unit and you need to press
Stop/Exit button to go back to the ready state without performing any operation.
2.1.2 Resetting the Life Counter of the Fuser Unit
<Function>
This function allows you to reset the page counter of the fuser unit and increase the number of
replacement times by one.
<Operating Procedure>
(1) Press the 3 and 9 buttons at the same time in the ready state.
The "Reset Menu / Drum" will appear on the LCD.
(2) Press the
(3) Press the OK button.
The "Fuser / 1. Reset 2. Exit" will appear on the LCD.
(4) Press the 1 button when resetting the page counter of the fuser unit. Press the 2 button if
not resetting.
(5) The "Fuser / Accepted" will appear on the LCD if pressing the 1 button. The page counter
of the fuser unit is reset, and the number of replacement times is increased by one. Then,
the machine returns to the ready state.
If pressing the 2 button, the machine returns to the Fuser and you need to press Stop/Exit
button to go back to the ready state without performing any operation.
button a few times to select "Belt unit".
button a few times to select "Fuser".
5-40