Brother DCP-9040CN Service Manual page 404

Hide thumbs Also See for DCP-9040CN:
Table of Contents

Advertisement

< WSW24 >
Selector No.
1
Maximum OGM recording time
2
Time length from CML ON to
3
start of pseudo ring backtone
4
transmission
5
Attenuator for playback of
|
ICM/OGM to the line
8
- Selectors 1 and 2: Maximum OGM recording time
These selectors set the allowable maximum recording time for an OGM.
- Selectors 3 and 4: Time length from CML ON to start of pseudo ring backtone transmission
These selectors set the length of time from CML-ON up to the start of pseudo ring
backtone transmission.
In models with OGM facilities, the settings made by these selectors also apply to the
length of time from CML-ON up to the start of OGM transmission.
- Selectors 5 through 8: Attenuator for playback of ICM/OGM to the line
Setting two or more selectors to "1" produces addition of attenuation assigned to each
selector.
This setting is not limited by selector 8 on WSW23.
Function
No. 1
No. 3
App. 1-29
Setting and Specifications
2
0
0: 15 sec.
0
1: 20 sec.
1
0: 30 sec.
1
1: 50 sec.
4
0
0: 4 sec.
0
1: 3 sec.
1
0: 2 sec.
1
1: 1 sec.
0: 0 dB
1: 8 dB
0: 0 dB
1: 4 dB
0: 0 dB
1: 2 dB
0: 0 dB
1: 1 dB
Confidential